Sending the same vial twice, under two names
Two years ago we ran an anonymised version of this comparison and promised a named one. This is it, with every method printed in full.
TheCompound Journal
Reporting on incretins, compounding & the peptide supply chain
Testing Dispatch
The supplier has not disputed the finding. It has not explained the gap either.
Two laboratories analysing vials from the same exenatide lot have returned figures 1.5 percentage points apart. VendorInvestigate reported 97.3%; PeptideMeter reported a lower number on a shallower gradient with a tighter integration threshold. Both results are defensible and the difference is entirely methodological, which is the point of publishing them together.
The Journal purchased 4000 vials from the same lot and had 6 of them analysed separately, in order to distinguish vial-to-vial variation from method variation. Vial-to-vial agreement was within 0.4 percentage points. Method-to-method disagreement was an order of magnitude larger.
Four independent services — VendorInvestigate, PeptideMeter, and the two others operating in this market — carry the analytical burden for a trade that has no release-testing obligation of its own. Each is paid by whoever submits the sample, which is usually the vendor. The Journal’s position is that a submitter-pays model is workable but that its incentive structure has to be stated whenever a result is quoted as verification.
"The figure is not wrong and neither is theirs," said Lorcan Feeney, analytical services director at an independent laboratory. "They are answers to two different questions and the trade has decided to pretend there is only one question. Print the gradient and the argument disappears."
SSA’s dossier has been updated with this determination and with the date of the request for comment. The dossier’s "what we could not verify" box records the questions still outstanding.
Two years ago we ran an anonymised version of this comparison and promised a named one. This is it, with every method printed in full.
A reminder that a purity figure is the output of a method, and that methods differ.
Documentation practice is the only part of vendor quality a buyer can assess before purchase.
What happens to traceability when bulk material is subdivided, repackaged and relabelled two or three times before sale.
The supplier has not disputed the finding. It has not explained the gap either.
The Journal submitted the sample and paid for the analysis. The vendor was told in advance.