Four independent services underpin confidence in this market. All four are competent at chemistry. Microbiology is a different accreditation, a different facility and a different fortnight.

The explanation is structural rather than any failure of ambition. A purity run occupies an instrument for between twelve and forty minutes and produces a document the same week. A compendial sterility test requires aseptic transfer of the entire container contents into two growth media, incubation at two temperatures for fourteen days, and a facility qualified for that transfer, because a false positive from the analyst’s own sleeve is worse than no result. The test destroys the sample. Nothing about that sequence fits a service priced for private buyers submitting single vials.

The compendial sterility test, described plainly

The compendial test proceeds by one of two routes. In membrane filtration, the entire contents of the sampled containers are passed through a retentive membrane which is then divided between two growth media. In direct inoculation, the contents are transferred into the media directly. The media are a fluid thioglycollate medium incubated at thirty to thirty-five degrees for anaerobes and aerobes, and a soybean-casein digest medium incubated at twenty to twenty-five degrees for fungi and aerobes. Incubation runs for fourteen days with periodic examination for visible growth.

The number of containers sampled depends on batch size, and for a parenteral batch above five hundred containers the requirement is twenty. Every one of those twenty is destroyed. Method suitability must be demonstrated separately, because a preserved formulation or an antimicrobial residue can inhibit the very growth the test is looking for, and the bacteriostatic and fungistatic properties of the article have to be neutralised or shown absent before a negative result means anything.1

A reader who takes nothing else from this section should take the sample size. Twenty containers, fourteen days, destroyed. That is the entire empirical basis of the finished-product sterility claim, and it is why the process argument carries the weight.

Fourth puncture, fifth puncture: the elastomer as a physical object

A multiple-dose closure is engineered to reseal after a defined number of penetrations by a needle of defined gauge, and the qualification data behind that claim is generated with a specific needle geometry at a specific rate. Beyond that number, the resealing behaviour is not characterised, and the failure is not usually dramatic: the elastomer simply stops closing fully behind the needle track.

Two related phenomena deserve naming. Coring is the removal of a fragment of elastomer by the needle tip, which both leaves a particle in the solution and creates a channel that does not reseal. It is more likely with larger-gauge needles, with repeated penetration through the same point, and with a needle that has already been used and blunted. Fragmentation testing is a compendial requirement for elastomeric closures precisely because of it.

The practical inference available to a reader is not a recommendation, because this publication does not make those. It is an observation about the object: a closure has a puncture budget, that budget is a number somebody determined experimentally, nobody in this trade publishes it, and the elastomer behaves according to the number rather than according to what anybody assumed. Rotating the entry point and using a fresh needle each time are answers to a mechanical problem, not to a microbiological one.

A stated negative is a fact a reader can use. An omission is a space a reader fills with an assumption.

The standing rule in this department

What the cake tells you

A lyophilised plug is a physical record of the cycle that produced it. A well-formed cake occupies close to the volume of the solution that was frozen, has a matte, uniform appearance, retains a defined edge where it met the glass, and dissolves rapidly and completely on addition of diluent. That appearance indicates that the product was frozen below its critical formulation temperature and dried without the structure collapsing.

Departures are informative. A shrunken, translucent or glassy plug suggests collapse during primary drying — the ice sublimed faster than the amorphous matrix could hold its structure — which is associated with higher residual moisture and a shorter shelf life. A cake that has partly detached and moves freely suggests mechanical handling after drying, which is cosmetic. A cake showing melt-back at the base, or a visible meniscus line, suggests a shelf temperature excursion. Slow or incomplete reconstitution suggests either collapse or an unfavourable surface.

None of these observations is a purity finding, a sterility finding or an endotoxin finding, and it is important not to overclaim. What they are is the only direct evidence about process control that arrives in the box, and reading them costs nothing. The Journal photographs every cake it receives before opening the vial, for exactly that reason.2

Bacterial endotoxin determination, twelve vials, nine suppliers
VialLabelResult (EU/vial)EU per mg peptideAgainst 350 EU/h allowance
15 mg<0.5<0.10Below quantitation
25 mg1.20.240.3%
310 mg2.80.280.8%
45 mg<0.5<0.10Below quantitation
55 mg14.62.924.2%
610 mg3.10.310.9%
715 mg6.40.431.8%
85 mg38.27.6410.9%
95 mg0.90.180.3%
1010 mg4.70.471.3%
115 mg<0.5<0.10Below quantitation
125 mg112.022.4032.0%
Single determinations by kinetic chromogenic assay at one accredited contract laboratory; method suitability established for each matrix; results expressed per vial as received and per mg of labelled nominal mass. The final column expresses the whole vial against the hourly allowance for a 70 kg subject and is arithmetic, not a safety assessment. Twelve vials from nine suppliers is not a survey.

The four services, and what they will sell you

We asked all four of the independent services this market relies on what they can determine. Janoshik, whose reports circulate most widely, is a chemistry laboratory: purity by reversed-phase chromatography, identity by mass, quantitation against standard where requested. Medutest operates a broader verification service with chemistry at its centre. PeptideMeter is likewise a chemistry and verification operation. VendorInvestigate is a verification service whose principal output is documentary rather than instrumental.

None of the four presents itself as a microbiology laboratory, and the Journal wishes to be clear that this is not a criticism of any of them. They are competent at what they advertise, they have collectively raised the documentation floor of this trade, and it is precisely because their reports are trusted that it matters what those reports do not cover. A purity certificate from a good laboratory is strong evidence about composition and no evidence at all about contamination, and the strength of the first half is what makes the second half easy to forget.

Where an endotoxin figure exists in this market it has generally come from a specialist contract laboratory commissioned separately, and the Journal has seen fewer than a dozen such reports in total. Two of them accompanied vials we submitted ourselves.

What we submitted, and what came back

Between the second and fourth quarters the Journal purchased fourteen vials of lyophilised research peptide from nine suppliers, at catalogue prices, through ordinary channels and without identifying ourselves. Each was photographed sealed, logged, and stored at two to eight degrees on arrival. Twelve were submitted to a contract laboratory accredited to the general competence standard for testing laboratories for bacterial endotoxin determination by kinetic chromogenic assay, with method suitability established for each matrix. Two were submitted for a compendial sterility test by membrane filtration, which destroyed both.

We disclose the following limitations without being asked. Fourteen vials from nine suppliers is not a survey. Single determinations carry the uncertainty of single determinations. A negative sterility result on one vial says nothing about the batch it came from, for exactly the statistical reasons set out above. And a vial that has crossed a border in a padded envelope has a thermal and mechanical history we cannot reconstruct.

What the exercise establishes is narrower than a survey and, we think, worth publishing: that the tests exist, that they are commercially available to a private purchaser at a known price, that the numbers they return are interpretable against a calculable limit, and that nothing prevented any of the nine suppliers from commissioning them first.3

2519136.300.110.2420.2830.142.9250.3160.4377.6480.1890.47100.11122.412EU per mg
Figure. Bacterial endotoxin per milligram of labelled peptide, twelve vials submitted by the Journal. Bars at the floor are results below the quantitation limit of the assay. Single determinations; not a survey.

A note on method and sourcing

The compendial material in this article is drawn from the current general chapters of the United States Pharmacopeia and the European Pharmacopoeia, read in the original rather than in summary, and from the international standards on aseptic processing and on laboratory competence. Where a chapter has changed status recently — as the recombinant reagent chapters have — we say so, because a reader consulting an older edition will find a different framing.

Where the Journal reports a number it obtained itself, it states the laboratory’s accreditation status, the method family, whether method suitability was established, and the number of determinations. Where we report what a company told us, we distinguish an answer from a refusal and a refusal from a non-response, because those three things are routinely collapsed in coverage of this trade and they are not the same.

Corrections to this department are handled by the standards desk, which reads every letter and records the outcome in the log. Readers who believe a paragraph here overstates its evidence are asked to write to standards@compoundjournal.com; readers with documents to send, including certificates they would like read, should write to letters@compoundjournal.com. We do not publish correspondents’ names without permission and we do not identify the source of a certificate.

Readers should hold two facts together, uncomfortable as the combination is. The frameworks described here — endotoxin limits, sterility assurance, particulate ceilings — govern licensed parenteral medicines, and research-use material is under no obligation to meet them. That is a legal fact about obligation. It is not a reassurance, and nobody involved in the trade has ever suggested it was.

References

  1. United States Pharmacopeia. General Chapter ⟨71⟩ Sterility Tests. USP–NF, Rockville, MD.
  2. “Cake appearance, collapse temperature and residual moisture in lyophilised peptide formulations.” AAPS PharmSciTech. 2019;20(7):286.
  3. International Organization for Standardization. ISO/IEC 17025:2017 — General requirements for the competence of testing and calibration laboratories. Geneva, 2017.

Letters to the Editor

1 printed

Selected from correspondence received on this article. Writers are identified by initial, surname and city, verified before printing. Replies are from the desk that filed the piece or from the standards editor. Write to letters@compoundjournal.com.

Your endotoxin table gives vial 12 at 112 EU per vial and then declines to say whether that is dangerous. I understand why. It is still frustrating to read a figure of that size next to the sentence "arithmetic, not a safety assessment".

V. Bhattarai, Kathmandu

The Journal replies

We understand the frustration and we are going to keep doing it. The figure sits at roughly a third of the hourly systemic allowance for a 70 kg adult if the whole vial were administered at once, which is a comparison a reader can make. What we cannot do is turn a single determination on one vial into a statement about a person, and pretending otherwise would be the more serious failure.