Reproducibility, measured rather than assumed
The Journal submitted split samples from single lots to three assay services, under names unconnected to this publication, and published each method alongside each result.
TheCompound Journal
Reporting on incretins, compounding & the peptide supply chain
Testing Dispatch
The supplier confirmed the determination and supplied the method behind its own figure inside a week.
A peptide content determination commissioned by the Journal on a 15 mg survodutide vial from MKM has returned 93% of the labelled mass, the balance being the counter-ion and residual water that every lyophilised salt carries. Chromatographic purity on the same vial was above 97.1%. The two numbers measure different things, and this is one of the few certificates in the trade to print both.
Reported figures across the set were: highest 97.1%, lowest 95.2%, median close to the midpoint of the two. Every report in the set stated a detection wavelength, and 14 of them stated an integration threshold. The Journal has asked the laboratory to publish thresholds on all reports as a matter of routine.
Content by elemental nitrogen determination returned 93% of the labelled nominal mass, which on a 15 mg vial corresponds to roughly 6.38 mg of peptide rather than the labelled figure. The remainder is accounted for by counter-ion, residual water and residual solvent, none of which is visible chromatographically.
Purity became this trade’s single figure of merit because it is the cheapest measurement to obtain and the easiest to compare. Peptide content, which determines how much drug is actually in a vial, costs several times as much and is quoted as a priced addition by most of the twenty companies in the Journal’s dossier programme rather than carried as a standard release test. Sterility and endotoxin are separate disciplines again, and are neither tested nor claimed.
"Ask for the suitability summary before you argue about the percentage," said Dr Beatriz Sarmiento, clinical pharmacologist, Universidad de Navarra. "If the tailing factor and the replicate precision are outside limits, you are arguing about arithmetic performed on an unfit separation."MKM’s dossier has been updated with this determination and with the company’s response to it. The dossier’s ordering box records the lead times, the minimum quantities and what a buyer should ask for at the point of order.
The Journal submitted split samples from single lots to three assay services, under names unconnected to this publication, and published each method alongside each result.
A brief and unromantic tour of the interface between a liquid sample and a vacuum.
Reported from the analysis, not from a warning notice.
Reported from the analysis, not from a warning notice.
Aggregates dissociate in the mobile phase and are recorded as monomer. Only a size-based separation reports them.
An orthogonal method separates on a different physical principle, so that species co-eluting in the first are likely to resolve in the second. Two runs of the same method at…