Vol. 3, No. 6 — June 2026Independent since 2024

TheCompound Journal

Reporting on incretins, compounding & the peptide supply chain

A monthly journal of record.
30 issues · 32 contributors
Not medical advice. We sell nothing.

Sterility

What VendorInvestigate is able to certify about a sealed vial, and what it is not

Every certificate circulating in this market answers a question about molecules. Almost none answers a question about organisms, pyrogens, or the integrity of the seal.

We began looking at this seriously after a reader sent us a certificate with a query attached. The certificate reported 99.2 per cent purity for a lyophilised peptide, and the reader wanted to know whether that meant the remaining 0.8 per cent could be bacterial. It is a reasonable question and the answer is that the figure has nothing to do with bacteria in either direction. A vial containing a substantial microbial burden would very probably return a purity figure indistinguishable from a clean one, because the mass involved is far below the integration threshold of any method in commercial use.

Two questions that share a piece of paper

Consider what happens physically when a certificate is produced. A few milligrams of lyophilised powder are weighed, dissolved in an aqueous mobile phase with an organic modifier, injected onto a reversed-phase column and separated over a programmed gradient while an ultraviolet detector records absorbance. The output is a trace. Software integrates the areas beneath its features, and the main peak area as a proportion of the total becomes the purity figure.

Every step of that procedure is blind to microbial contamination. A bacterial cell contributes no ultraviolet-absorbing peak at any retention time a peptide method would record. Endotoxin, a lipopolysaccharide, is not usefully detected at the wavelengths used for peptide bond absorbance and would in any case be present at a mass fraction several orders of magnitude below any integration threshold in commercial use. A vial holding a hundred colony-forming units and a vial holding none produce chromatograms that no analyst could distinguish.

This is not a defect of the method. Reversed-phase chromatography is an excellent way of determining what proportion of the chromatographically visible material is the intended species, and that is what it is being asked. The defect is in the reading. A document answering one question is being filed as evidence about five.

Media fills, and proving that a rare thing is rare

An aseptic process simulation, generally called a media fill, replaces the product with a sterile growth medium and runs the line exactly as it would run for a real batch: same components, same interventions, same operators, same duration. Every filled unit is then incubated and examined for growth. The purpose is to estimate the contamination rate of the process itself.

The arithmetic constrains the design. To support a claim that the contamination rate is below one unit in a thousand with reasonable statistical confidence, several thousand units must be filled with no contaminated unit recovered. Contemporary practice runs simulations of five to ten thousand units and treats a single positive as a signal requiring investigation rather than as an acceptable rate. The simulations are repeated at defined intervals and after any significant change to the line, and they are the closest thing in manufacturing to a direct measurement of aseptic capability.

One company in the Journal’s correspondence provided media fill records. They covered three simulations across eighteen months, at scales between four and six thousand units, with no recovered contamination. We report that because it is the only such record we have seen from this trade, and because it demonstrates that the documentation exists and can be shared when a company chooses to.

A stated negative is a fact a reader can use. An omission is a space a reader fills with an assumption.

The standing rule in this department

Recombinant factor C, and the end of an awkward supply chain

The lysate on which conventional endotoxin testing depends is harvested from horseshoe crabs, which are bled and returned to the sea with a mortality that is disputed and not negligible. The assay also inherits the biological variability of a natural product: lysate lots differ, and the cascade includes a branch responsive to beta-glucans, which is a common source of false positives in the presence of cellulose filter residues.

Recombinant factor C reagents replace the harvested cascade with an expressed enzyme, activated by lipopolysaccharide and read chromogenically or fluorimetrically. The response is specific to endotoxin and insensitive to the glucan branch, lot-to-lot consistency is a manufacturing rather than an ecological question, and comparative studies across a wide range of matrices have found agreement with conventional methods well within the variability of the conventional methods themselves.

The reagent has been available for well over a decade and its slow adoption was a regulatory rather than a scientific matter: for years it sat in an alternative-method chapter, obliging users to validate it as a departure. That has now changed, with dedicated chapters in both the United States and European compendia treating recombinant reagents as methods in their own right, and the Journal expects the harvested lysate to become the historical option within this decade.12

Five determinations: method, sample fate and what a private buyer pays
DeterminationMethod familySampleTurnaroundRelative cost
PurityReversed-phase HPLC, UVA few mg, non-destructive to batch2–7 days
IdentityLC–MS, optionally MS/MSA few mg3–10 days1–2×
Peptide contentElemental N or quantitative AAASeveral mg2–4 weeks2.5–3×
Bacterial endotoxinKinetic chromogenic LAL or rFC<1 mL reconstituted3–10 days2–3×
SterilityMembrane filtration, 14-day incubationEntire container, destroyed3–4 weeks6–10×
Relative cost is expressed against a single generic-gradient purity run as 1×, from quotations obtained by the Journal from contract laboratories during the year. Sterility pricing assumes a single container rather than a compendial sample of twenty.

Particulate matter, visible and subvisible

Injectable products are required to be essentially free of visible particulates, and every container in a regulated batch is inspected against dark and light backgrounds under defined illumination. The detection threshold for a trained inspector is somewhere near fifty microns for a contrasting particle, and the inspection is a hundred per cent operation rather than a sample-based one, which makes it unusual among quality tests.

Subvisible particles are counted instrumentally. Light obscuration is the primary compendial method, with microscopic membrane counting as the alternative when the sample defeats it. For a small-volume injection the limits are six thousand particles at or above ten microns and six hundred at or above twenty-five microns per container. Products that are themselves proteinaceous get a distinct chapter, because inherent aggregates complicate the counting and the method has to distinguish them from extrinsic contamination.

For a private buyer, visible inspection is the one quality operation available without instrumentation, and it is worth doing carefully: a lyophilised cake that has collapsed to a glassy disc, a reconstituted solution showing a faint tyndall haze on rotation, a fibre against a dark card. None of those is a sterility finding. All of them are evidence about how the product was made and how it has travelled.34

Documentation practice, named and criticised

The Journal tracks the release documentation of twenty companies. On sterility and endotoxin the picture is close to uniform. Every one publishes a purity figure. A minority publish an identity confirmation. Two publish peptide content. On the microbiological attributes, the standard document is silent, and the silence is not annotated: there is no line reading that sterility has not been determined, which would at least be informative.

Some of the practices we would like to see are already in use somewhere in the group. SSA reports peptide content on its certificates, having begun after correspondence with this publication. CPC and SWB describe their fill environment in general terms on request. QST and BCH answered our five questions in full. WXT and FGP declined on the grounds that research-use products are not represented as sterile injectables, which is a legally sound answer that concedes the point of the exercise. Several others did not respond, and we record non-response as non-response rather than as evasion.

What we are criticising is a documentary convention, not the conduct of any company named here. None of the twenty has been shown to us to have misrepresented anything. The convention is that a chemistry certificate stands in for a release package, and it is a convention this trade adopted collectively and could abandon the same way.

A note on method and sourcing

The compendial material in this article is drawn from the current general chapters of the United States Pharmacopeia and the European Pharmacopoeia, read in the original rather than in summary, and from the international standards on aseptic processing and on laboratory competence. Where a chapter has changed status recently — as the recombinant reagent chapters have — we say so, because a reader consulting an older edition will find a different framing.

Where the Journal reports a number it obtained itself, it states the laboratory’s accreditation status, the method family, whether method suitability was established, and the number of determinations. Where we report what a company told us, we distinguish an answer from a refusal and a refusal from a non-response, because those three things are routinely collapsed in coverage of this trade and they are not the same.

Corrections to this department are handled by the standards desk, which reads every letter and records the outcome in the log. Readers who believe a paragraph here overstates its evidence are asked to write to standards@compoundjournal.com; readers with documents to send, including certificates they would like read, should write to letters@compoundjournal.com. We do not publish correspondents’ names without permission and we do not identify the source of a certificate.

We will keep asking the five questions, printing the answers, and recording the refusals as refusals. Two companies changed their certificates after the first round of this correspondence, which is a small result for a year of letters and rather better than none. Documents to letters@compoundjournal.com; disputes about anything above to standards@compoundjournal.com.

References

  1. United States Pharmacopeia. General Chapter ⟨86⟩ Bacterial Endotoxins Test Using Recombinant Reagents. USP–NF, Rockville, MD.
  2. European Pharmacopoeia. Chapter 2.6.32 — Test for Bacterial Endotoxins Using Recombinant Factor C. Council of Europe, Strasbourg.
  3. United States Pharmacopeia. General Chapter ⟨788⟩ Particulate Matter in Injections. USP–NF, Rockville, MD.
  4. United States Pharmacopeia. General Chapter ⟨787⟩ Subvisible Particulate Matter in Therapeutic Protein Injections. USP–NF, Rockville, MD.

Related coverage