Leucine, isoleucine, and a difference no balance can measure
Deamidation adds 0.98 daltons. On a low-resolution instrument at incretin molecular weights, that is inside the noise.
TheCompound Journal
Reporting on incretins, compounding & the peptide supply chain
Excursions
Storage instructions in this market are close to uniform and almost never accompanied by the study that would justify them. Uniformity is a sign of convention, not of measurement.
We asked twenty companies three questions in writing. Has a formal stability study been performed on this product, under what conditions and for how long. Is residual moisture determined on the finished lyophilised product, and against what specification. Is the shelf life stated on the certificate a retest date or an expiry date, and what data supports it. Six companies answered all three. Five answered one or two. Nine did not reply to two messages sent four weeks apart. As always we record a refusal as a refusal and a silence as a silence.
Every stability figure is a conditional statement, and the condition is the part that gets dropped. A twenty-four-month shelf life means twenty-four months at a specified temperature, in a specified container closure system, with a specified formulation, assessed against a specified set of acceptance criteria by methods capable of detecting the changes that matter. Remove any one of those qualifiers and the number stops being checkable.
The trade routinely reports the number and none of the qualifiers. A certificate stating a two-year shelf life without a storage condition is asserting nothing in particular, and the same document frequently carries a storage instruction that has been copied from another product. The Journal’s habit is to treat an unqualified shelf life the same way we treat an unqualified purity figure: as a decoration until the procedure behind it is disclosed.
There is also a vocabulary problem worth clearing up. An expiry date states that material should not be used beyond it. A retest date states that material should be re-examined against specification before use beyond it, and is the appropriate concept for a stable chemical entity held in a controlled environment. Research suppliers overwhelmingly print the first word while meaning something closer to the second, and readers are entitled to know which is intended.1
Two methods dominate. Karl Fischer titration determines water specifically, by a stoichiometric reaction with iodine, and is the reference method; the coulometric variant works on the small sample masses a single vial provides. Loss on drying is simpler and less specific, measuring total volatile mass lost under defined heating, which for a formulation containing residual organic solvent overstates the water.
Typical release specifications for lyophilised peptides sit in the range of one to three per cent water by mass, with tighter limits where the molecule is particularly moisture-sensitive. The relationship to stability is not linear. Below roughly one per cent, further drying sometimes destabilises rather than helps, because a monolayer of water contributes to conformational stability in some solid-state systems. Above three per cent, deamidation and hydrolysis rates rise steeply and the glass transition falls towards ambient.
None of the twenty companies the Journal tracks reports residual moisture as a standard release test. Two will provide a figure on request. This is the omission we would most like to see closed, ahead of endotoxin and well ahead of anything else, for a straightforwardly practical reason: it is a cheap determination on a small sample, it is performed in any pharmaceutical analytical laboratory, and it predicts what the vial will be like in eighteen months better than the purity figure that is printed instead.
Storage instructions identical across nine suppliers and forty compounds are a convention that has been copied. Copying is not measuring.
Noor Haddadin, Supply Chain EditorA stability study is only as good as the analytical method behind it, and the requirement has a name: the method must be stability-indicating, meaning it must resolve the parent compound from its degradation products and quantify the change. Establishing that is done by forced degradation — deliberately stressing the material with acid, base, oxidant, heat and light — and demonstrating that the resulting products are separated from the parent and from each other with adequate peak purity.
Almost nothing sold as a purity determination in this market has been validated that way. A generic peptide gradient run for twelve minutes may perfectly well resolve the parent from its two largest process impurities and entirely fail to resolve it from its isoaspartate isomer or a closely related oxidation product. The number it returns is a purity figure, not a stability measurement, and using a series of such figures to argue that a product has not degraded is a category error.
The compendial guidance on analytical validation is explicit about specificity, and about demonstrating it against the degradation products the molecule can actually form. The gap between that expectation and practice in this trade is not a matter of dishonesty. It is that the method being sold was designed for a different purpose and is being asked a question it was not built to answer.2
| Pathway | Residues at risk | Accelerated by | Mass change | Detected by |
|---|---|---|---|---|
| Deamidation | Asn (fast at Asn-Gly), Gln | Water, pH above neutral, heat | None (isoAsp) or +1 Da | Shallow RP gradient; isoAsp-specific methods |
| Oxidation | Met, Trp, His, Cys, Tyr | Peroxides, trace metals, light, oxygen | +16 Da and multiples | LC–MS; RP shift |
| Aggregation | Sequence-dependent | Interfaces, shaking, freeze-thaw | Multiples of monomer | Size-exclusion; light scattering |
| Hydrolysis | Asp-Pro, Asp-Gly, N-terminal Gln | Low pH, heat, water | Fragments | RP-HPLC and MS on fragments |
| Racemisation | Asp, Ser, Cys | Heat, extremes of pH | None | Chiral or highly discriminating RP methods |
| Sequence dependence is the rule. This table describes tendencies across peptides, not the behaviour of any particular molecule, and the mass-change column is the reason identity confirmation by molecular ion alone is insufficient for stability purposes. | ||||
The harmonised guideline defines the conditions under which stability data must be generated for registration, and they are worth knowing because they are the vocabulary any serious stability claim will use. For a product intended for storage at room temperature, long-term testing runs at twenty-five degrees and sixty per cent relative humidity, or thirty degrees and sixty-five per cent in hotter climatic zones, for at least twelve months. Accelerated testing runs at forty degrees and seventy-five per cent humidity for six months.
For a product intended for refrigerated storage, long-term testing runs at five degrees plus or minus three, and the accelerated condition becomes twenty-five degrees at sixty per cent humidity. Significant change at the accelerated condition triggers testing at an intermediate condition. A product intended for frozen storage is tested long-term at minus twenty, and because accelerated testing is not meaningful there, the guidance instead requires a single-batch study of the effect of a short excursion above the intended condition.
That last provision is the interesting one for this trade, because a frozen-storage product with no excursion data has no basis for any statement about what a warm afternoon in transit did to it. Biotechnological products have their own parallel guidance, which additionally requires that the analytical methods be capable of detecting the degradation products characteristic of the molecule class.3
The Journal tracks release documentation from twenty companies whose names appear on labels in this market. On stability the picture is close to uniform. All twenty state a storage condition. Nineteen state a shelf life. None reports residual moisture as standard. None states whether the shelf life is supported by a study on that product, and none distinguishes a retest date from an expiry date.
Where practice differs it is worth naming. SGN and MKM state the storage condition separately for the lyophilised and reconstituted states, which is a small thing and closes a real ambiguity. KP and HJ ship in amber glass. QST provided, on request, the conditions and duration of a study on one product, which is the only such document we have received. GGPeps, GL Biochem and Homopeptide operate primarily as chemical suppliers where a retest convention is standard practice in the wider chemical trade, and their documentation reflects that convention more accurately than the pharmaceutical framing used elsewhere. TFC, JEEP, QSC and ERP answered part of our questionnaire; several others did not reply.
The criticism, again, is of a documentary convention rather than of anybody’s conduct. No company named here has been shown to us to have misstated a result. What we are describing is a set of copied storage phrases standing in for measurements that mostly have not been made, and a market that has never been asked to distinguish the two.
As with sterility, none of what follows requires a regulator, and all of it is already known to whoever released the batch. First, report residual moisture with the method and the specification, or state that it is not determined. Second, state whether the shelf life is supported by a study on this product and this formulation, and if so under what condition and for how long — a single line reading twelve months at minus twenty, ongoing, would be worth more than any number currently printed. Third, use the words retest and expiry correctly, and say which applies.
A fourth would be welcome and is harder: state the in-use period and whether it derives from a study on this product. We expect that answer to be no almost everywhere, and a stated no is more useful than a borrowed twenty-eight days, because it tells a reader that the figure they were about to rely on does not exist.
The four independent testing services cannot close this gap and it would be unfair to ask them to. Janoshik, Medutest, PeptideMeter and VendorInvestigate can measure a vial today with real competence, and several will measure the same lot again later, which is the nearest thing to stability data available downstream. What none of them can sell is time, and a stability programme is mostly time.
The finding the Journal least wanted and most trusts is that the transit excursions everybody worries about are probably not the largest exposure in this supply chain. A dried cake at low moisture tolerates a warm afternoon. A reconstituted vial in a refrigerator door for six weeks, with no in-use study behind the number that justified the six weeks, is a different proposition, and it attracts almost no attention at all.
Selected from correspondence received on this article. Writers are identified by initial, surname and city, verified before printing. Replies are from the desk that filed the piece or from the standards editor. Write to letters@compoundjournal.com.
Your table of degradation pathways lists racemisation and then says it is essentially never reported. If it is never reported, on what basis do you list it as a real risk rather than a theoretical one?
— K. Sivertsen, Bergen
On the basis of the synthesis and analytical literature, where epimer formation during solid-phase assembly and during storage at extremes of pH is well characterised. What is missing is not evidence that it occurs but evidence about how much of it is present in any particular commercial vial, which is a different absence and the one we should have named.
The mean kinetic temperature explanation is the clearest I have read anywhere, including in the training my employer paid for. I have printed the sidebar and put it on the wall of the dispatch room.
— J. Vasilenko, Chisinau
On amber glass: it is not merely cheap, it is standard in the wider chemical supply trade for anything with a chromophore. The fact that this market ships peptides in clear glass is a sign of who is doing the filling more than of any decision about photostability.
— T. Oyelowo, Abeokuta
Parcel 7 reached thirty-eight degrees for nearly four hours and you then tell readers not to worry unduly. I accept the solid-state argument. I would still like to know what the material looked like on analysis, and your article does not say.
— S. Bergqvist, Malmö
A fair criticism of the reporting. Parcel 7 was submitted for purity determination on arrival and returned a figure within a percentage point of the supplier’s stated value, which is consistent with the solid-state argument and proves very little on its own, since we had no pre-shipment measurement on that vial. The design fault is ours: a shipment study without a paired baseline sample cannot answer the question we most wanted answered, and the next round will.
Your section on freezing reconstituted solution stops short of the obvious question, which I will therefore ask. If a phosphate buffer shifts pH substantially on freezing, does that not mean the freezer is actively worse than the refrigerator for a buffered formulation, rather than merely unproven?
— N. Halvorsen, Trondheim
For a phosphate-buffered formulation, plausibly yes, and the mechanism is well documented. We stopped short because the magnitude is formulation-specific and because most reconstituted research vials are in unbuffered water or bacteriostatic water, where the argument is about the interface rather than about pH. We should have made that distinction in the text instead of leaving a gap for you to find.
Deamidation adds 0.98 daltons. On a low-resolution instrument at incretin molecular weights, that is inside the noise.
What happens to traceability when bulk material is subdivided, repackaged and relabelled two or three times before sale.
The Journal has read several hundred certificates from twenty companies. We set out what the documents actually cover, and what a reader is filling in from imagination.
We describe each pathway in enough chemical detail to explain why it is invisible to the method the trade uses, because that is the part which has practical consequences.
Follow the resin, not the catalogue.
Documentation practice is the only part of vendor quality a buyer can assess before purchase.