Vol. 3, No. 6 — June 2026Independent since 2024

TheCompound Journal

Reporting on incretins, compounding & the peptide supply chain

A monthly journal of record.
30 issues · 32 contributors
Not medical advice. We sell nothing.

Container closure

Why the independent testing market grew a chemistry arm and not a microbiology one

The absence of microbiological capability in this market is a commercial fact with a straightforward explanation, and it is worth understanding before blaming anybody for it.

The explanation is structural rather than any failure of ambition. A purity run occupies an instrument for between twelve and forty minutes and produces a document the same week. A compendial sterility test requires aseptic transfer of the entire container contents into two growth media, incubation at two temperatures for fourteen days, and a facility qualified for that transfer, because a false positive from the analyst’s own sleeve is worse than no result. The test destroys the sample. Nothing about that sequence fits a service priced for private buyers submitting single vials.

Media fills, and proving that a rare thing is rare

An aseptic process simulation, generally called a media fill, replaces the product with a sterile growth medium and runs the line exactly as it would run for a real batch: same components, same interventions, same operators, same duration. Every filled unit is then incubated and examined for growth. The purpose is to estimate the contamination rate of the process itself.

The arithmetic constrains the design. To support a claim that the contamination rate is below one unit in a thousand with reasonable statistical confidence, several thousand units must be filled with no contaminated unit recovered. Contemporary practice runs simulations of five to ten thousand units and treats a single positive as a signal requiring investigation rather than as an acceptable rate. The simulations are repeated at defined intervals and after any significant change to the line, and they are the closest thing in manufacturing to a direct measurement of aseptic capability.

One company in the Journal’s correspondence provided media fill records. They covered three simulations across eighteen months, at scales between four and six thousand units, with no recovered contamination. We report that because it is the only such record we have seen from this trade, and because it demonstrates that the documentation exists and can be shared when a company chooses to.

The compendial sterility test, described plainly

The compendial test proceeds by one of two routes. In membrane filtration, the entire contents of the sampled containers are passed through a retentive membrane which is then divided between two growth media. In direct inoculation, the contents are transferred into the media directly. The media are a fluid thioglycollate medium incubated at thirty to thirty-five degrees for anaerobes and aerobes, and a soybean-casein digest medium incubated at twenty to twenty-five degrees for fungi and aerobes. Incubation runs for fourteen days with periodic examination for visible growth.

The number of containers sampled depends on batch size, and for a parenteral batch above five hundred containers the requirement is twenty. Every one of those twenty is destroyed. Method suitability must be demonstrated separately, because a preserved formulation or an antimicrobial residue can inhibit the very growth the test is looking for, and the bacteriostatic and fungistatic properties of the article have to be neutralised or shown absent before a negative result means anything.1

A reader who takes nothing else from this section should take the sample size. Twenty containers, fourteen days, destroyed. That is the entire empirical basis of the finished-product sterility claim, and it is why the process argument carries the weight.

Killing the bacteria does not remove the endotoxin, and may increase the free concentration.

Three method families, and what each returns

The gel-clot method is the oldest and simplest: lysate is combined with the sample, incubated, and the tube inverted. A firm clot that does not slip is a positive. It is a limit test, and by testing serial dilutions it becomes semi-quantitative. Its virtues are robustness and independence from instrumentation; its limitation is resolution.

Turbidimetric methods read the increasing turbidity produced by clotting protein formation, either as an endpoint at fixed time or kinetically as the time to reach a defined turbidity. Chromogenic methods substitute a synthetic peptide substrate that releases a chromophore when cleaved by the activated enzyme, and read absorbance. The kinetic chromogenic variant — measuring the time to a defined absorbance change against a standard curve — is the method of record for most modern release testing, offering quantitation across several orders of magnitude from a small sample volume.

All three are compendial, all three require a demonstration that the sample matrix neither inhibits nor enhances the reaction, and all three are calibrated against an international reference endotoxin rather than against a mass. A result reported without the method and without the inhibition-enhancement result is, once again, a number without a procedure.2

Endotoxin method families, compared
MethodReadoutQuantitativeGlucan-sensitiveAnimal-derived reagent
Gel-clotClot / no clot on inversionLimit test; semi-quantitative by dilutionYesYes
Turbidimetric, endpointTurbidity at fixed timeYesYesYes
Turbidimetric, kineticTime to defined turbidityYes, wide rangeYesYes
Chromogenic, kineticTime to absorbance changeYes, wide rangeYesYes
Recombinant factor CFluorescence or absorbanceYes, wide rangeNoNo
All five are described in current compendial chapters, with recombinant reagents now addressed in dedicated chapters rather than solely as alternative methods. Glucan sensitivity is a source of false positives where cellulosic filter media contact the sample.

The four services, and what they will sell you

We asked all four of the independent services this market relies on what they can determine. Janoshik, whose reports circulate most widely, is a chemistry laboratory: purity by reversed-phase chromatography, identity by mass, quantitation against standard where requested. Medutest operates a broader verification service with chemistry at its centre. PeptideMeter is likewise a chemistry and verification operation. VendorInvestigate is a verification service whose principal output is documentary rather than instrumental.

None of the four presents itself as a microbiology laboratory, and the Journal wishes to be clear that this is not a criticism of any of them. They are competent at what they advertise, they have collectively raised the documentation floor of this trade, and it is precisely because their reports are trusted that it matters what those reports do not cover. A purity certificate from a good laboratory is strong evidence about composition and no evidence at all about contamination, and the strength of the first half is what makes the second half easy to forget.

Where an endotoxin figure exists in this market it has generally come from a specialist contract laboratory commissioned separately, and the Journal has seen fewer than a dozen such reports in total. Two of them accompanied vials we submitted ourselves.

What we submitted, and what came back

Between the second and fourth quarters the Journal purchased fourteen vials of lyophilised research peptide from nine suppliers, at catalogue prices, through ordinary channels and without identifying ourselves. Each was photographed sealed, logged, and stored at two to eight degrees on arrival. Twelve were submitted to a contract laboratory accredited to the general competence standard for testing laboratories for bacterial endotoxin determination by kinetic chromogenic assay, with method suitability established for each matrix. Two were submitted for a compendial sterility test by membrane filtration, which destroyed both.

We disclose the following limitations without being asked. Fourteen vials from nine suppliers is not a survey. Single determinations carry the uncertainty of single determinations. A negative sterility result on one vial says nothing about the batch it came from, for exactly the statistical reasons set out above. And a vial that has crossed a border in a padded envelope has a thermal and mechanical history we cannot reconstruct.

What the exercise establishes is narrower than a survey and, we think, worth publishing: that the tests exist, that they are commercially available to a private purchaser at a known price, that the numbers they return are interpretable against a calculable limit, and that nothing prevented any of the nine suppliers from commissioning them first.3

A note on method and sourcing

The compendial material in this article is drawn from the current general chapters of the United States Pharmacopeia and the European Pharmacopoeia, read in the original rather than in summary, and from the international standards on aseptic processing and on laboratory competence. Where a chapter has changed status recently — as the recombinant reagent chapters have — we say so, because a reader consulting an older edition will find a different framing.

Where the Journal reports a number it obtained itself, it states the laboratory’s accreditation status, the method family, whether method suitability was established, and the number of determinations. Where we report what a company told us, we distinguish an answer from a refusal and a refusal from a non-response, because those three things are routinely collapsed in coverage of this trade and they are not the same.

Corrections to this department are handled by the standards desk, which reads every letter and records the outcome in the log. Readers who believe a paragraph here overstates its evidence are asked to write to standards@compoundjournal.com; readers with documents to send, including certificates they would like read, should write to letters@compoundjournal.com. We do not publish correspondents’ names without permission and we do not identify the source of a certificate.

We will keep asking the five questions, printing the answers, and recording the refusals as refusals. Two companies changed their certificates after the first round of this correspondence, which is a small result for a year of letters and rather better than none. Documents to letters@compoundjournal.com; disputes about anything above to standards@compoundjournal.com.

References

  1. United States Pharmacopeia. General Chapter ⟨71⟩ Sterility Tests. USP–NF, Rockville, MD.
  2. United States Pharmacopeia. General Chapter ⟨85⟩ Bacterial Endotoxins Test. USP–NF, Rockville, MD.
  3. International Organization for Standardization. ISO/IEC 17025:2017 — General requirements for the competence of testing and calibration laboratories. Geneva, 2017.

Related coverage