Reading a barrel: the graduation that is not the one you think
Dead space in the needle hub is a real and calculable loss, and it matters more at small volumes than anybody expects.
TheCompound Journal
Reporting on incretins, compounding & the peptide supply chain
Page 3 of 12 of this archive, newest first.
Dead space in the needle hub is a real and calculable loss, and it matters more at small volumes than anybody expects.
The intervention with the clearest evidence is the one nobody frames as an intervention: adjusting the dose.
We looked at what the dose-ranging data supports about going higher, and it is thinner and less flattering than the market assumes.
System suitability is the set of checks demonstrating that the instrument and method were performing adequately when your sample was injected. It is recorded as a matter of…
Where the curve flattens, what flattens with it, and what does not.
What a single-stage mass measurement supports, what it excludes, and the gap between the two.
An intact mass measurement establishes elemental composition, at best. The number of distinct sequences consistent with a given composition is astronomically large.
A drug that delays gastric emptying complicates the assumption behind every fasting instruction in perioperative medicine. The professional bodies have moved twice on this…
We looked at what the dose-ranging data supports about going higher, and it is thinner and less flattering than the market assumes.
The air shot before a pen injection removes air from the cartridge and confirms flow. Skipping it can mean a materially reduced dose, and it is skipped constantly.
Holding a dose before a procedure has a kinetic problem: a weekly drug with a seven-day half-life cannot be cleared by skipping one injection.
Almost nothing in the standard management repertoire has been tested in a randomised trial in this specific population. We say what is extrapolated and from where.
Chromatographic software does not integrate every fluctuation in the baseline. It applies a threshold, and the threshold changes the reported purity by amounts that matter…
The evidence base here is the insulin injection-technique literature, which is large and transfers well on tissue questions.
Peptide bonds absorb strongly near 214 nm; aromatic side chains absorb near 280 nm. A method reading at 280 is blind to any fragment lacking an aromatic residue.
None of what a checkable identity statement requires is commercially sensitive, and all of it is known to whoever produced the document.
This piece takes the measurement apart into the decisions it is made of, because each decision moves the answer.
The arithmetic of significant figures, applied to a document that routinely reports four of them.
The two ionisation techniques in general use produce different charge distributions, different adducts and different failure modes. Certificates almost never say which was…
A pharmacist catches most of these in licensed practice. In this market there is no pharmacist, so the checks have to be structural.