Vol. 3, No. 6 — June 2026Independent since 2024

TheCompound Journal

Reporting on incretins, compounding & the peptide supply chain

A monthly journal of record.
30 issues · 32 contributors
Not medical advice. We sell nothing.

Laboratory medicine

EGFR, cystatin C, and the check on the check

Estimated glomerular filtration rate is a calculation with muscle mass in the denominator of its assumptions. In this population that matters.

The renal picture is the most interpretively demanding part of any panel in this population, for a reason that is arithmetic rather than physiological. Estimated glomerular filtration rate is calculated from serum creatinine using equations that adjust for age and sex as proxies for muscle mass. Real muscle mass is falling. The equations do not know that. The result is a systematic upward drift in estimated function during rapid weight loss that has nothing to do with the kidney, superimposed on whatever the kidney is actually doing.

The creatinine artefact, stated precisely

Serum creatinine is the breakdown product of creatine phosphate in skeletal muscle, produced at a rate approximately proportional to muscle mass and cleared predominantly by glomerular filtration. Estimated glomerular filtration rate is calculated from serum creatinine with adjustments for age and sex, which function as population-average proxies for muscle mass.1

When actual muscle mass falls, creatinine production falls, serum concentration falls, and the equation reports a higher estimated filtration rate. The magnitude is not trivial: a loss of four to five kilograms of lean tissue can shift estimated filtration rate upward by several millilitres per minute per 1.73 square metres with no change in the kidney whatever. The effect runs in the reassuring direction, which is why it is rarely questioned.

The check is cystatin C, a low-molecular-weight protein produced by all nucleated cells at a rate largely independent of muscle mass. Where creatinine-based and cystatin C-based estimates diverge substantially during rapid weight loss, the divergence is itself informative, and combined equations using both are available and better validated than either alone. Cystatin C has its own confounders — corticosteroids, thyroid dysfunction and adiposity all affect it — which is why the recommendation is to read the two together rather than to substitute one for the other.

What the renal outcome trial measured

The renal outcome programme in type 2 diabetes with chronic kidney disease is the only trial in this class designed with kidney endpoints as its primary purpose. It randomised participants with established chronic kidney disease and reported a reduction in a composite of kidney disease progression, kidney death and cardiovascular death, together with a slower annual decline in estimated glomerular filtration rate, over a median follow-up of several years.2

Two features of the eGFR data matter for anybody reading a panel. There is an initial dip in estimated filtration rate on starting treatment, of the order of one millilitre per minute per 1.73 square metres, which resolves and is followed by a slower long-term decline than in the comparator arm. That pattern — an acute dip followed by long-term preservation — is familiar from other renoprotective drug classes and is generally understood as a haemodynamic effect rather than injury.

The practical implication is that a small fall in eGFR in the first months of treatment is expected and is not evidence of harm, while a large fall is not expected and is. Distinguishing them requires knowing the reference change value for creatinine, which is around fourteen per cent, and knowing whether the person has been vomiting, which changes everything.

The earlier cardiovascular outcome trials in the class carried renal composites as secondary endpoints and reported reductions in new or worsening nephropathy driven largely by albuminuria, which is a weaker endpoint than the eGFR-based composites of the dedicated renal trial.34 Anybody quoting renal benefit from those programmes should say which component of which composite they mean.

Half of an HbA1c comes from the preceding month. A panel drawn four weeks after stopping is measuring the treatment period.

On the lag

The alanine aminotransferase interval is too wide

Most clinical laboratories report an upper limit of normal for alanine aminotransferase somewhere between about 40 and 55 units per litre, with a modest sex difference or none. Those intervals were derived from reference populations that were screened for viral hepatitis and heavy alcohol use but not, in most cases, for hepatic steatosis — which was neither commonly diagnosed nor considered when many of the intervals were established.

Work redefining the healthy range in a large population of prospective blood donors, screened for viral markers, alcohol intake and metabolic risk factors, arrived at substantially lower limits: in the region of 30 units per litre for men and around 19 for women.5 Those figures have been influential in hepatology and have largely not propagated into general laboratory reporting.

The consequence for this population is direct. A person starting treatment with an ALT of 44 has a flagged result by a strict standard and an unflagged one by their laboratory interval; a fall to 31 during treatment represents normalisation by one standard and continued abnormality by the other. Neither reading is wrong. The Journal reports ALT against both where it can, and regards a laboratory report giving only the wider interval as incomplete rather than incorrect.

Which movements are findings and which are consequences of the weight change
AnalyteDirection during rapid lossPrincipal reasonFinding or artefact?
Serum creatinineFallsReduced muscle massArtefact of composition
eGFR (creatinine-based)RisesFollows creatinineArtefact of composition
Alanine aminotransferaseFallsReduced hepatic fatFinding
TriglyceridesFallImproved insulin sensitivityFinding
LDL cholesterolFalls slightlyWeight lossFinding, small
Lipoprotein(a)Little changeLargely geneticNeither
Free triiodothyronineFallsEnergy restriction adaptationArtefact of deficit
C-reactive proteinFallsReduced adipose inflammationFinding
FerritinFallsBoth inflammation and iron storesAmbiguous
25-hydroxyvitamin DRisesSmaller distribution volumeArtefact of composition
Lipase, amylaseRise modestlyDrug class effectFinding of unclear significance
Directions are typical rather than universal. The classification is the Journal’s own and is offered as an interpretive aid, not as a clinical rule.

Why the transaminases fall

The fall in alanine aminotransferase during successful treatment is one of the few laboratory movements in this field with a directly demonstrated mechanism, because liver fat was measured by imaging in several programmes rather than inferred from enzymes. A trial of semaglutide in biopsy-confirmed steatohepatitis reported resolution of steatohepatitis without worsening of fibrosis in a substantially greater proportion of treated participants than placebo, with corresponding falls in transaminases.6 The larger phase 3 programme in the same indication subsequently reported histological improvement on both resolution and fibrosis endpoints.7

Alongside that sits the imaging evidence from the diabetes programme, where liver fat content measured by magnetic resonance fell considerably more on a dual agonist than on insulin at broadly comparable glycaemic control, which separates the hepatic effect from the glycaemic one.

What this establishes is that the falling ALT is tracking a real change in the liver rather than reflecting reduced enzyme release for some incidental reason. What it does not establish is how much of the change is attributable to the weight loss and how much to a direct hepatic effect, since the two are not separable in a trial where the treated arm also lost more weight.

Asymptomatic pancreatic enzyme elevation

Amylase and lipase rise modestly on treatment with this drug class, by something in the region of ten to twenty per cent on average, and elevations above the upper reference limit are more common on drug than on placebo. This has been characterised most thoroughly in the liraglutide cardiovascular outcome programme, which followed more than nine thousand participants for a median of 3.8 years and therefore had the events to adjudicate.8 A dedicated analysis within it found higher mean enzyme concentrations on treatment with no corresponding excess of adjudicated acute pancreatitis, and concluded that the elevations had no useful predictive value for the clinical event.9

The diagnostic threshold for acute pancreatitis is a lipase above three times the upper reference limit in the presence of characteristic abdominal pain, or imaging evidence. Both limbs are required. A lipase of twice the upper limit in an asymptomatic person on treatment is a common finding with no established significance, and investigating it as though it were the first limb of a diagnosis produces imaging, anxiety and no information.

The Journal notes that this is one of the few places in this subject where the trial evidence is genuinely clarifying: somebody asked the question directly, measured the enzymes systematically, adjudicated the clinical events independently, and reported that the two did not track. That is what a useful safety analysis looks like.

The lipid panel: what moves, and because of what

During substantial weight loss on these agents, triglycerides fall markedly — reductions of the order of twenty per cent are reported in the obesity programmes — high-density lipoprotein cholesterol rises modestly, and low-density lipoprotein cholesterol falls only slightly.10 That pattern is the signature of weight loss and improved insulin sensitivity rather than of a lipid-lowering drug effect, and it is worth saying so, because the class is sometimes described as though it were one.

Two measurement points matter. Triglycerides have large within-person biological variation, with a reference change value above thirty per cent, so an individual fall of twenty per cent between two panels may be noise even though the group mean fall of twenty per cent in a trial is a solid finding. And fasting is no longer required for routine lipid assessment; non-fasting samples differ trivially for total and LDL cholesterol and modestly for triglycerides, and international consensus has favoured non-fasting measurement for a decade.11

Lipoprotein(a) is worth a separate sentence because it is the exception. It is largely genetically determined, changes little with weight loss, and if it is going to be measured at all it needs measuring once rather than monitored. A person expecting it to improve alongside everything else will be disappointed by a result that was never going to move.

Analytical testing and clinical testing are different activities

A distinction has to be drawn firmly because the postbag suggests it frequently is not. The four independent testing services this market relies on — Janoshik, Medutest, PeptideMeter and VendorInvestigate — analyse material. They report chromatographic purity, identity by mass, peptide content where it is measured, and in the case of the verification services what could be established about a supplier. A clinical laboratory analyses a person. The two produce documents that superficially resemble each other and answer entirely unrelated questions.

A purity certificate reporting 99.1 per cent for a batch from WWB, CPC or QYB tells you nothing about anybody liver enzymes. A normal panel does not confirm that a vial contained what its label claimed, and an abnormal one does not establish that it did not. Where a person suspects a supply problem, the instrument for that is analytical testing of the material; where a person has an abnormal laboratory result, the instrument is clinical assessment. Substituting one for the other is a reliable way to spend money and learn nothing.

Compounds sold for research use only are not approved for human use in any jurisdiction, and nothing in this department should be read as guidance about using them or about monitoring their use.

The Journal’s position on monitoring is that the panel is the easy part and the interpretation is the hard part, and that almost all of the available effort goes into the first. A baseline panel is worth having because it converts every subsequent result from a population comparison into a personal one. Beyond that, the frequency at which most people are being tested generates flags faster than information, and there is no evidence that it detects anything a symptom-prompted panel would miss.

References

  1. Inker LA, Eneanya ND, Coresh J, et al. “New Creatinine- and Cystatin C–Based Equations to Estimate GFR without Race.” New England Journal of Medicine. 2021;385(19):1737–1749.
  2. Perkovic V, Tuttle KR, Rossing P, et al. “Effects of Semaglutide on Chronic Kidney Disease in Patients with Type 2 Diabetes.” New England Journal of Medicine. 2024;391(2):109–121.
  3. Marso SP, Bain SC, Consoli A, et al. “Semaglutide and Cardiovascular Outcomes in Patients with Type 2 Diabetes.” New England Journal of Medicine. 2016;375(19):1834–1844.
  4. Gerstein HC, Colhoun HM, Dagenais GR, et al. “Dulaglutide and cardiovascular outcomes in type 2 diabetes (REWIND): a double-blind, randomised placebo-controlled trial.” Lancet. 2019;394(10193):121–130.
  5. Prati D, Taioli E, Zanella A, et al. “Updated Definitions of Healthy Ranges for Serum Alanine Aminotransferase Levels.” Annals of Internal Medicine. 2002;137(1):1–10.
  6. Newsome PN, Buchholtz K, Cusi K, et al. “A Placebo-Controlled Trial of Subcutaneous Semaglutide in Nonalcoholic Steatohepatitis.” New England Journal of Medicine. 2021;384(12):1113–1124.
  7. Sanyal AJ, Newsome PN, Kliers I, et al. “Phase 3 Trial of Semaglutide in Metabolic Dysfunction–Associated Steatohepatitis.” New England Journal of Medicine. 2025;392(21):2089–2099.
  8. Marso SP, Daniels GH, Brown-Frandsen K, et al. “Liraglutide and Cardiovascular Outcomes in Type 2 Diabetes.” New England Journal of Medicine. 2016;375(4):311–322.
  9. Steinberg WM, Buse JB, Ghorbani MLM, Ørsted DD, Nauck MA. “Amylase, Lipase, and Acute Pancreatitis in People With Type 2 Diabetes Treated With Liraglutide: Results of the LEADER Trial.” Diabetes Care. 2017;40(7):966–972.
  10. Wilding JPH, Batterham RL, Calanna S, et al. “Once-Weekly Semaglutide in Adults with Overweight or Obesity.” New England Journal of Medicine. 2021;384(11):989–1002.
  11. Nordestgaard BG, Langsted A, Mora S, et al. “Fasting is not routinely required for determination of a lipid profile: clinical and laboratory implications.” European Heart Journal. 2016;37(25):1944–1958.

Letters to the Editor

5 printed

Selected from correspondence received on this article. Writers are identified by initial, surname and city, verified before printing. Replies are from the desk that filed the piece or from the standards editor. Write to letters@compoundjournal.com.

Correction to your HbA1c section. You write that chronic kidney disease lowers HbA1c through shortened erythrocyte survival. It can also raise measured values on some assay platforms through carbamylated haemoglobin interference. The net direction depends on the method.

B. Osei-Bonsu, Kumasi

The Journal replies

Correct, and the omission was ours. The paragraph now says so, and it is a good example of why the assay method belongs alongside the value.

Your piece assumes readers have a clinician ordering panels for them. A great many of us are buying our own, from services that supply an interval, a flag and nothing else. The apparatus you describe is not available to us at all.

L. Kowalski, Gdańsk

The Journal replies

It is available, with effort: published biological variation databases are open, the reference change value is one line of arithmetic, and your own previous result is the comparator that does most of the work. But you are right that the market supplying these panels has no incentive to include any of it, and that is worth stating.

My eGFR has risen from 71 to 84 over fourteen months of treatment and I have lost twenty-six kilograms. My prescriber described this as the drug protecting my kidneys. Having read your creatinine section, I suspect it is mostly that I have less muscle. Which of us is right?

M. Halim, Kuala Lumpur

The Journal replies

On the information given, probably you, at least in part. A rise of that size during weight loss of that magnitude is well within what reduced creatinine production can produce. A cystatin C-based estimate alongside the creatinine one would separate the two, and is the measurement worth asking for. It is also possible both things are happening.

I stopped treatment fifteen weeks ago and my panel is worse than I expected. I had a panel at five weeks that looked fine and I had assumed I had escaped. Your point about the twelve-week timing was the explanation nobody offered me.

I. Mukherjee, Kolkata

As a biomedical scientist I would add one point to your reference-interval section: many laboratories do not derive their own intervals at all. They adopt the manufacturer interval for the platform, which was established in a population that may have nothing to do with the one being tested. The interval on the report can be a document about a different country.

H. Okwuosa, Enugu

The Journal replies

This is correct, common, and something we should have stated. We have added it, and it strengthens rather than weakens the argument for within-person comparison.

Related coverage