Independent analysis puts a SGN survodutide lot at 97.0%, against 92.8% on the certificate
A reminder that a purity figure is the output of a method, and that methods differ.
TheCompound Journal
Reporting on incretins, compounding & the peptide supply chain
Container closure
The Journal wrote to twenty companies asking five specific questions about sterility assurance. We report the response rate, the substance and the refusals.
Eleven of the twenty replied within the month. Of those, four answered all five questions, three answered between one and three, and four replied to say that the questions did not apply because the products are sold for research use and are not represented as sterile injectables. That last answer is legally accurate and it is the most important sentence in this article, because it describes precisely the gap between what is being sold and what buyers believe they are buying.
A sterilising filter is not an unlimited barrier. Its qualification is expressed as a retention capability under a defined challenge — conventionally a high titre of a small bacterial species per square centimetre of membrane — and its performance in use depends on the load presented to it. A bulk solution carrying a heavy microbial burden presents a filter with a harder problem than one carrying a light burden, and it presents a second problem the filter cannot address at all: the endotoxin released by organisms that die upstream passes through the membrane unimpeded.
Regulated manufacture therefore specifies a pre-filtration bioburden limit, tests against it on every batch, and treats an excursion as an investigation rather than a curiosity. The specification is usually expressed in colony-forming units per hundred millilitres, and a well-controlled process runs far below it.
Of the twenty companies the Journal wrote to, four stated that pre-filtration bioburden is determined on every batch, three stated that it is determined periodically, and the remainder did not answer the question. We regard that distribution as the single most informative result of the correspondence, because bioburden testing is inexpensive, is performed on the bulk rather than the finished container, and is the earliest point at which a problem is cheap to fix.
Endotoxin is a structural component of the outer membrane of Gram-negative bacteria: a lipopolysaccharide with a lipid A anchor that is the pyrogenic moiety, a core oligosaccharide, and a variable O-antigen chain. It is shed during growth and released in quantity on cell lysis, which means that killing a bacterial population does not remove its endotoxin and may increase the free concentration.
Three physical properties make it a separate discipline. It is thermally robust, surviving autoclave conditions with little loss of pyrogenicity, so terminal sterilisation is not a depyrogenation step. It is small and amphipathic, forming aggregates that pass a 0.22 micron membrane without difficulty, so sterilising filtration is not a depyrogenation step either. And it is active in humans at very low mass — the threshold pyrogenic dose corresponds to something in the region of a nanogram per kilogram of body weight.
The practical consequence is stark. A vial can pass a sterility test, contain no viable organism of any kind, and carry an endotoxin burden many times a defensible parenteral limit, because the organisms responsible died somewhere upstream in a water system, a holding tank or a poorly stored component.1
Twenty containers, fourteen days, destroyed. That is the entire empirical basis of the finished-product sterility claim.
On the compendial sterility testBetween the second and fourth quarters the Journal purchased fourteen vials of lyophilised research peptide from nine suppliers, at catalogue prices, through ordinary channels and without identifying ourselves. Each was photographed sealed, logged, and stored at two to eight degrees on arrival. Twelve were submitted to a contract laboratory accredited to the general competence standard for testing laboratories for bacterial endotoxin determination by kinetic chromogenic assay, with method suitability established for each matrix. Two were submitted for a compendial sterility test by membrane filtration, which destroyed both.
We disclose the following limitations without being asked. Fourteen vials from nine suppliers is not a survey. Single determinations carry the uncertainty of single determinations. A negative sterility result on one vial says nothing about the batch it came from, for exactly the statistical reasons set out above. And a vial that has crossed a border in a padded envelope has a thermal and mechanical history we cannot reconstruct.
What the exercise establishes is narrower than a survey and, we think, worth publishing: that the tests exist, that they are commercially available to a private purchaser at a known price, that the numbers they return are interpretable against a calculable limit, and that nothing prevented any of the nine suppliers from commissioning them first.2
| Vial | Label | Result (EU/vial) | EU per mg peptide | Against 350 EU/h allowance |
|---|---|---|---|---|
| 1 | 5 mg | <0.5 | <0.10 | Below quantitation |
| 2 | 5 mg | 1.2 | 0.24 | 0.3% |
| 3 | 10 mg | 2.8 | 0.28 | 0.8% |
| 4 | 5 mg | <0.5 | <0.10 | Below quantitation |
| 5 | 5 mg | 14.6 | 2.92 | 4.2% |
| 6 | 10 mg | 3.1 | 0.31 | 0.9% |
| 7 | 15 mg | 6.4 | 0.43 | 1.8% |
| 8 | 5 mg | 38.2 | 7.64 | 10.9% |
| 9 | 5 mg | 0.9 | 0.18 | 0.3% |
| 10 | 10 mg | 4.7 | 0.47 | 1.3% |
| 11 | 5 mg | <0.5 | <0.10 | Below quantitation |
| 12 | 5 mg | 112.0 | 22.40 | 32.0% |
| Single determinations by kinetic chromogenic assay at one accredited contract laboratory; method suitability established for each matrix; results expressed per vial as received and per mg of labelled nominal mass. The final column expresses the whole vial against the hourly allowance for a 70 kg subject and is arithmetic, not a safety assessment. Twelve vials from nine suppliers is not a survey. | ||||
The Journal tracks the release documentation of twenty companies. On sterility and endotoxin the picture is close to uniform. Every one publishes a purity figure. A minority publish an identity confirmation. Two publish peptide content. On the microbiological attributes, the standard document is silent, and the silence is not annotated: there is no line reading that sterility has not been determined, which would at least be informative.
Some of the practices we would like to see are already in use somewhere in the group. SSA reports peptide content on its certificates, having begun after correspondence with this publication. CPC and SWB describe their fill environment in general terms on request. QST and BCH answered our five questions in full. WXT and FGP declined on the grounds that research-use products are not represented as sterile injectables, which is a legally sound answer that concedes the point of the exercise. Several others did not respond, and we record non-response as non-response rather than as evasion.
What we are criticising is a documentary convention, not the conduct of any company named here. None of the twenty has been shown to us to have misrepresented anything. The convention is that a chemistry certificate stands in for a release package, and it is a convention this trade adopted collectively and could abandon the same way.
Nothing the Journal asks for here requires a regulator, an inspectorate or a change in the law, and none of it is commercially sensitive. All five items are already known to whoever released the batch.
First, state the fill route: aseptic or terminal, and if aseptic, in what class of environment. Second, state the pre-filtration bioburden result against its specification, or state that bioburden is not determined. Third, state whether the sterilising filter was integrity-tested after use. Fourth, report bacterial endotoxin per milligram of peptide, with the method and the inhibition-enhancement result, or state that it was not determined. Fifth, where a sterility test has been performed, state the batch size, the number of containers tested and the method, so that a reader can do the arithmetic in the section above. Every one of the five is an ordinary element of a release specification for a biological product, and none of them is an invention of this publication.3
A certificate carrying those five lines would remain a one-page document and would be worth several times what the current one is worth, principally because four of the five lines are permitted to say no. A stated negative is a fact a reader can use. An omission is a space a reader fills with an assumption, and the assumption is always more favourable than the truth would have been.
Precision about the scope of a criticism is part of the job, so it is worth spending a paragraph on what is not being said. This piece does not allege that any company named in it has sold contaminated material. It does not allege that any of them has concealed a result, falsified a document or misrepresented a test. It does not claim that the products discussed are dangerous, and it does not claim that they are safe, because neither claim is supportable from the evidence we have.
What the piece asserts is documentary. A certificate describing chemistry is being read as a release package covering microbiology. That mismatch is created by the format of the document rather than by anybody’s intent, and it is closed by adding lines rather than by changing behaviour.
There is also a legal point the Journal has no wish to elide. Research-use-only material is not approved for human use in any jurisdiction, is not required to meet parenteral standards, and is not represented by its sellers as meeting them. Everything in this article about endotoxin limits and sterility assurance describes the framework that would apply to a parenteral medicine. Applying that framework to a research chemical is a comparison, not a compliance requirement, and readers should hold both halves of that sentence at once.
The compendial material in this article is drawn from the current general chapters of the United States Pharmacopeia and the European Pharmacopoeia, read in the original rather than in summary, and from the international standards on aseptic processing and on laboratory competence. Where a chapter has changed status recently — as the recombinant reagent chapters have — we say so, because a reader consulting an older edition will find a different framing.
Where the Journal reports a number it obtained itself, it states the laboratory’s accreditation status, the method family, whether method suitability was established, and the number of determinations. Where we report what a company told us, we distinguish an answer from a refusal and a refusal from a non-response, because those three things are routinely collapsed in coverage of this trade and they are not the same.
Corrections to this department are handled by the standards desk, which reads every letter and records the outcome in the log. Readers who believe a paragraph here overstates its evidence are asked to write to standards@compoundjournal.com; readers with documents to send, including certificates they would like read, should write to letters@compoundjournal.com. We do not publish correspondents’ names without permission and we do not identify the source of a certificate.
The sterility half is not solvable within the current economics, and it would be dishonest to pretend otherwise. Fourteen days, two media, a destroyed container and a statistical yield that passes most contaminated batches: no commercial testing service can build a product out of that for private buyers, and none has tried. The honest position is that this attribute is not verifiable downstream and must be assured upstream or not at all.
A reminder that a purity figure is the output of a method, and that methods differ.
The most useful single addition to any purity determination is a second separation under a different pH or on a different stationary phase, and the second-most useful is a…
A 4 mm needle at ninety degrees without a skin pinch is adequate for essentially all adults. The persistence of 12.7 mm needles in this market is habit, not reasoning.
The sequence predicts the failure mode. A methionine predicts oxidation; an asparagine followed by a glycine predicts deamidation; a cysteine predicts disulphide scrambling.
Skin thickness at the standard injection sites is approximately two millimetres in adults and varies remarkably little with body mass. That single finding is why short…
Parts per million sound impressive until they are converted into daltons at the molecular weight of the thing being measured.