What changed at SGN in October, and what the company will not say about it
Documentation practice is the only part of vendor quality a buyer can assess before purchase.
TheCompound Journal
Reporting on incretins, compounding & the peptide supply chain
Stability
Reversed-phase chromatography runs in an organic, acidic mobile phase that dissociates most non-covalent aggregates on the way to the detector.
The single most consequential fact about deamidation is that the isoaspartate product has the same molecular weight as the parent peptide, because the rearrangement moves an atom rather than adding or removing one. A laboratory confirming identity by molecular ion mass alone will report a substantially deamidated preparation as the intended compound. Separation is possible — the isomers usually resolve on a sufficiently shallow reversed-phase gradient, and specialist methods resolve them reliably — but only if the method was designed to look. A twelve-minute generic gradient does not look.
Methionine oxidises to the sulfoxide and, under harsher conditions, the sulfone. Tryptophan oxidises through a series of products including kynurenine derivatives. Histidine and tyrosine are susceptible under metal-catalysed conditions, and free cysteine oxidises readily to disulphide. Each of these products differs from the parent by a defined mass increment, which makes oxidation the pathway most reliably detected by mass spectrometry: the sulfoxide is sixteen mass units heavier and unmistakable.
The interesting question is usually where the oxidant came from, and the answers are mundane. Trace transition metals leached from glass, stainless steel or a stopper catalyse oxidation of several residues. Peroxides accumulate in polysorbate surfactants during storage and are a well-documented source of methionine oxidation in formulated products. Dissolved oxygen in the diluent contributes. Light drives it, particularly for tryptophan, and light exposure during handling is entirely undocumented in this trade.
Practical consequences follow that are not obvious. A formulation containing a surfactant that has itself been stored warm for a year may oxidise a peptide that would have been perfectly stable in a plain aqueous vehicle. Headspace composition matters: vials backfilled with nitrogen behave differently from vials sealed under air, and the difference is a manufacturing choice recorded nowhere on the label.1
Backbone hydrolysis cleaves an amide bond outright and produces two fragments, each of which is a distinct chromatographic species and each of which is detectable by mass. It is generally slower than deamidation at ordinary storage conditions but becomes dominant at low pH and elevated temperature, which is one reason accelerated stability data for peptides extrapolates so poorly: the pathway that dominates at forty degrees may be irrelevant at five.
Certain positions are much more labile than others. Aspartate-proline and aspartate-glycine bonds hydrolyse relatively readily under acidic conditions. N-terminal glutamine can cyclise to pyroglutamate, losing ammonia. Peptides with an N-terminal sequence of the right geometry can form a diketopiperazine and shed the first two residues as a cyclic dipeptide, a route that is fast enough at neutral pH to matter for some sequences.
Racemisation at susceptible residues produces epimers that are chemically identical in composition and differ only in stereochemistry. They are among the hardest impurities to detect, requiring either a chiral method or a sufficiently discriminating reversed-phase separation, and they are essentially never reported. A vial can be nominally pure by every measurement on its certificate and contain a percentage of a diastereomer with unknown biological behaviour.
Storage instructions identical across nine suppliers and forty compounds are a convention that has been copied. Copying is not measuring.
Noor Haddadin, Supply Chain EditorA stability study is only as good as the analytical method behind it, and the requirement has a name: the method must be stability-indicating, meaning it must resolve the parent compound from its degradation products and quantify the change. Establishing that is done by forced degradation — deliberately stressing the material with acid, base, oxidant, heat and light — and demonstrating that the resulting products are separated from the parent and from each other with adequate peak purity.
Almost nothing sold as a purity determination in this market has been validated that way. A generic peptide gradient run for twelve minutes may perfectly well resolve the parent from its two largest process impurities and entirely fail to resolve it from its isoaspartate isomer or a closely related oxidation product. The number it returns is a purity figure, not a stability measurement, and using a series of such figures to argue that a product has not degraded is a category error.
The compendial guidance on analytical validation is explicit about specificity, and about demonstrating it against the degradation products the molecule can actually form. The gap between that expectation and practice in this trade is not a matter of dishonesty. It is that the method being sold was designed for a different purpose and is being asked a question it was not built to answer.2
| Parcel | Legs | Transit (days) | Arithmetic mean (°C) | MKT (°C) | Hours >25 °C | Max (°C) |
|---|---|---|---|---|---|---|
| 1 | Domestic road | 2 | 5.1 | 6.0 | 0.0 | 11.4 |
| 2 | Domestic road | 2 | 6.8 | 8.2 | 0.0 | 14.9 |
| 3 | Air + road | 4 | 13.2 | 17.1 | 9.5 | 28.6 |
| 4 | Air + road | 5 | 15.4 | 19.8 | 21.0 | 31.2 |
| 5 | Air + road | 4 | 11.9 | 14.6 | 6.5 | 26.9 |
| 6 | Air + road | 6 | 17.1 | 21.3 | 34.5 | 33.8 |
| 7 | Road only, cross-border | 7 | 18.6 | 24.4 | 46.0 | 38.0 |
| 8 | Air + road | 3 | 9.7 | 11.4 | 2.0 | 25.8 |
| 9 | Air, held at border | 11 (logger to day 5) | 14.8* | not computed | 18.5* | 29.4* |
| Loggers calibrated within the preceding twelve months, sampling at five-minute intervals, placed inside the insulated payload adjacent to the vials. Mean kinetic temperature computed with the conventional activation energy of approximately 83 kJ/mol. Asterisked figures for parcel 9 cover only the first five days, after which the memory was exhausted; the parcel was released after eleven days and the cake had visibly shrunk. Nine parcels is not a survey. | ||||||
The temptation with any stability programme is to run the accelerated condition, fit an Arrhenius relationship to the rate constants, and extrapolate to the intended storage temperature. For a single reaction with a temperature-independent mechanism that is sound. For peptides it frequently is not, and the reason is that different pathways have different activation energies.
Suppose a peptide degrades at five degrees principally by deamidation and at forty degrees principally by hydrolysis, with the second having a higher activation energy. Measuring total degradation at forty degrees measures mostly hydrolysis; extrapolating that rate down to five degrees predicts almost nothing about the deamidation that will actually dominate. Aggregation is worse still, because it is frequently nucleated by interfaces and mechanical stress rather than by thermal energy alone, and does not obey a simple temperature relationship at all.
The practical rule the Journal applies when reading a stability claim is to ask what condition the data was generated at and whether the degradation products were identified as well as quantified. Accelerated data that shows which products form is genuinely useful as a warning of what to watch for. Accelerated data reduced to a single percentage and extrapolated to a shelf life is a projection dressed as a measurement, and for this class of molecule it is a poor projection.
Photostability has its own guideline, its own defined light source options and its own exposure requirement expressed in lux hours of visible light and watt hours per square metre of near ultraviolet. Products are tested in the immediate container, and where they fail, in the marketing pack, and where they fail again the label carries a protection instruction. The chemistry is real: tryptophan and tyrosine absorb in the near ultraviolet and photo-oxidise, and photolytic disulphide cleavage is well documented.
Nothing about light exposure is recorded anywhere in the research-peptide supply chain. Vials are frequently supplied in clear glass. Photographs for listings are taken under studio lighting. Parcels are opened on kitchen counters. A reconstituted vial may sit on a shelf under a window for weeks. The cumulative exposure is unknown and unknowable, and it is plausibly a larger contributor to degradation than the transit excursions that attract all the attention.
The Journal makes one narrow observation rather than a recommendation, because recommendations are not this publication’s business. Amber glass, or a secondary carton, costs a fraction of a cent per unit and removes an uncontrolled variable entirely. Several of the twenty companies we track already ship in amber vials; most do not, and the ones that do not have not, as far as we can establish, generated any data suggesting it does not matter.3
Nobody can buy time, which is why this documentation gap is not going to be closed by a testing service. What can be done immediately is to distinguish a measurement from a convention: to say twelve months at minus twenty, ongoing, rather than two years, and to say that an in-use period has not been established for this product rather than borrowing one from a pen.
Selected from correspondence received on this article. Writers are identified by initial, surname and city, verified before printing. Replies are from the desk that filed the piece or from the standards editor. Write to letters@compoundjournal.com.
You draw a distinction between retest date and expiry date and then say suppliers use the wrong word. Which word do you think they should use, given that most of them have no study behind either?
— I. Mukherjee, Kolkata
Retest, with a stated interval and a note that no formal stability study supports it. That is an honest description of a chemical supplier’s position and it is standard practice in the wider chemical trade. Printing expiry implies a study exists, which is the specific inference we object to.
I would add one omission to your list. Nobody states the headspace gas. Nitrogen-backfilled vials and air-sealed vials behave differently for any oxidation-prone sequence, and it is a single word on a certificate.
— M. Halim, Kuala Lumpur
Parcel 7 reached thirty-eight degrees for nearly four hours and you then tell readers not to worry unduly. I accept the solid-state argument. I would still like to know what the material looked like on analysis, and your article does not say.
— L. Kowalski, Gdańsk
A fair criticism of the reporting. Parcel 7 was submitted for purity determination on arrival and returned a figure within a percentage point of the supplier’s stated value, which is consistent with the solid-state argument and proves very little on its own, since we had no pre-shipment measurement on that vial. The design fault is ours: a shipment study without a paired baseline sample cannot answer the question we most wanted answered, and the next round will.
On amber glass: it is not merely cheap, it is standard in the wider chemical supply trade for anything with a chromophore. The fact that this market ships peptides in clear glass is a sign of who is doing the filling more than of any decision about photostability.
— B. Osei-Bonsu, Kumasi
Documentation practice is the only part of vendor quality a buyer can assess before purchase.
Multiple-dose vials are designed for a defined number of punctures. Nobody counts, and the elastomer does not care whether anybody counts.
Documentation practice is the only part of vendor quality a buyer can assess before purchase.
The Journal submitted the sample and paid for the analysis. The vendor was told in advance.
The route did not close because of a rule about peptides.
Follow the resin, not the catalogue.