Holograms, QR codes and other things that are not verification
Reported from the analysis, not from a warning notice.
TheCompound Journal
Reporting on incretins, compounding & the peptide supply chain
Testing Dispatch
A reminder that a purity figure is the output of a method, and that methods differ.
Medutest has published a purity determination of 96.4% on a 2 mg vial of survodutide supplied by Homopeptide, against a figure of 92.6% on the certificate that accompanied the vial. The sample was submitted by the Journal in August 2024 as part of a continuing programme of arm’s-length purchasing, and the vendor was told before the order was placed that any result would be published.
Content by elemental nitrogen determination returned 96% of the labelled nominal mass, which on a 2 mg vial corresponds to roughly 8.61 mg of peptide rather than the labelled figure. The remainder is accounted for by counter-ion, residual water and residual solvent, none of which is visible chromatographically.
The Journal purchased 15 vials from the same lot at retail and had four of them analysed separately, in order to distinguish vial-to-vial variation from method variation. Vial-to-vial agreement was within 0.4 percentage points. Method-to-method disagreement was an order of magnitude larger.
Discrepancies of one to two percentage points between a supplier’s figure and an independent determination are common and usually explicable: a faster gradient resolves fewer impurities, a higher integration threshold discards more small peaks, and a wider solvent-front exclusion window removes early-eluting fragments from the calculation altogether. None of that is misconduct. All of it is invisible unless the method is disclosed.
"Ask for the suitability summary before you argue about the percentage," said Dr Sirichai Boonmee, peptide chemist, Chulalongkorn University. "If the tailing factor and the replicate precision are outside limits, you are arguing about arithmetic performed on an unfit separation."Homopeptide’s dossier has been updated with this determination and with the company’s response to it. The dossier’s ordering box records the lead times, the minimum quantities and what a buyer should ask for at the point of order.
Reported from the analysis, not from a warning notice.
Every third-party report in this market describes a sample somebody chose to send. That choice is outside the laboratory’s control and outside its records.
Reported from the analysis, not from a warning notice.
The interval between manufacture and analysis is the most under-read figure on the page, and the one most likely to matter by the time a vial is opened.
Reversed-phase chromatography runs in an organic, acidic mobile phase that dissociates most non-covalent aggregates on the way to the detector.
The report states the gradient, the wavelength and the integration threshold, which is more than most.