Independent analysis puts a FGP exenatide lot at 96.3%, against 92.6% on the certificate
The supplier confirmed the determination and supplied the method behind its own figure inside a week.
TheCompound Journal
Reporting on incretins, compounding & the peptide supply chain
Testing Dispatch
The result is unremarkable. What the report states alongside it is not.
An independent purity determination on liraglutide material sold by GGPeps has returned 97.6%, a figure 4.0 percentage points above the number printed on the accompanying certificate, which the supplier had reported against a shorter gradient and a tighter threshold. The analysis was performed by PeptideMeter on a vial the Journal bought as an ordinary retail customer in April 2026 and posted unopened.
Reported figures across the set were: highest 97.6%, lowest 96.6%, median close to the midpoint of the two. Every report in the set stated a detection wavelength, and 13 of them stated an integration threshold. The Journal has asked the laboratory to publish thresholds on all reports as a matter of routine.
The Journal purchased 13 vials from the same lot at retail and had four of them analysed separately, in order to distinguish vial-to-vial variation from method variation. Vial-to-vial agreement was within 0.4 percentage points. Method-to-method disagreement was an order of magnitude larger.
Discrepancies of one to two percentage points between a supplier’s figure and an independent determination are common and usually explicable: a faster gradient resolves fewer impurities, a higher integration threshold discards more small peaks, and a wider solvent-front exclusion window removes early-eluting fragments from the calculation altogether. None of that is misconduct. All of it is invisible unless the method is disclosed.
"The useful thing in that report is not the percentage, it is the system suitability data," said Havel Novotný, independent laboratory quality manager. "It is the only part that tells you whether the percentage means anything."
GGPeps’s dossier has been updated with this determination and with the company’s response to it. The dossier’s ordering box records the lead times, the minimum quantities and what a buyer should ask for at the point of order.
The supplier confirmed the determination and supplied the method behind its own figure inside a week.
Documentation practice is the only part of vendor quality a buyer can assess before purchase.
The Journal’s standing position: a mass that matches is necessary evidence of identity and nowhere near sufficient.
Documentation practice is the only part of vendor quality a buyer can assess before purchase.
The supplier confirmed the determination and supplied the method behind its own figure inside a week.
The report states the gradient, the wavelength and the integration threshold, which is more than most.