Sterility

The question no chromatogram has ever answered

Every certificate circulating in this market answers a question about molecules. Almost none answers a question about organisms, pyrogens, or the integrity of the seal.

We began looking at this seriously after a reader sent us a certificate with a query attached. The certificate reported 99.2 per cent purity for a lyophilised peptide, and the reader wanted to know whether that meant the remaining 0.8 per cent could be bacterial. It is a reasonable question and the answer is that the figure has nothing to do with bacteria in either direction. A vial containing a substantial microbial burden would very probably return a purity figure indistinguishable from a clean one, because the mass involved is far below the integration threshold of any method in commercial use.

Two questions that share a piece of paper

Consider what happens physically when a certificate is produced. A few milligrams of lyophilised powder are weighed, dissolved in an aqueous mobile phase with an organic modifier, injected onto a reversed-phase column and separated over a programmed gradient while an ultraviolet detector records absorbance. The output is a trace. Software integrates the areas beneath its features, and the main peak area as a proportion of the total becomes the purity figure.

Every step of that procedure is blind to microbial contamination. A bacterial cell contributes no ultraviolet-absorbing peak at any retention time a peptide method would record. Endotoxin, a lipopolysaccharide, is not usefully detected at the wavelengths used for peptide bond absorbance and would in any case be present at a mass fraction several orders of magnitude below any integration threshold in commercial use. A vial holding a hundred colony-forming units and a vial holding none produce chromatograms that no analyst could distinguish.

This is not a defect of the method. Reversed-phase chromatography is an excellent way of determining what proportion of the chromatographically visible material is the intended species, and that is what it is being asked. The defect is in the reading. A document answering one question is being filed as evidence about five.

Why nothing in this market is terminally sterilised

Where a product will tolerate it, moist-heat terminal sterilisation is the preferred route by a wide margin, for the simple reason that the object subjected to the lethal process is the sealed, filled, finished container. There is no subsequent opportunity for contamination, and the lethality delivered can be measured directly through the load.

Peptides make poor candidates. Autoclave conditions accelerate hydrolysis of the amide backbone, deamidation of asparagine and glutamine residues, and aggregation, and a cycle sufficient to guarantee microbial lethality will typically destroy a measurable fraction of the active substance. Lyophilised presentations do not escape the problem, because the solution is filled before it is dried, and the sterility of the finished cake is inherited from the sterility of that solution and the environment of the fill.

The consequence is that every product in this market is aseptically processed. That places the entire burden of sterility assurance on filtration, environmental control, component preparation and operator technique — precisely the four things about which the trade publishes nothing. The Journal states this as a structural observation, not as an accusation: the same is true of many legitimate aseptically filled products, and the difference lies in whether an inspectorate has looked.1

A stated negative is a fact a reader can use. An omission is a space a reader fills with an assumption.

The standing rule in this department

Recombinant factor C, and the end of an awkward supply chain

The lysate on which conventional endotoxin testing depends is harvested from horseshoe crabs, which are bled and returned to the sea with a mortality that is disputed and not negligible. The assay also inherits the biological variability of a natural product: lysate lots differ, and the cascade includes a branch responsive to beta-glucans, which is a common source of false positives in the presence of cellulose filter residues.

Recombinant factor C reagents replace the harvested cascade with an expressed enzyme, activated by lipopolysaccharide and read chromogenically or fluorimetrically. The response is specific to endotoxin and insensitive to the glucan branch, lot-to-lot consistency is a manufacturing rather than an ecological question, and comparative studies across a wide range of matrices have found agreement with conventional methods well within the variability of the conventional methods themselves.

The reagent has been available for well over a decade and its slow adoption was a regulatory rather than a scientific matter: for years it sat in an alternative-method chapter, obliging users to validate it as a departure. That has now changed, with dedicated chapters in both the United States and European compendia treating recombinant reagents as methods in their own right, and the Journal expects the harvested lysate to become the historical option within this decade.23

Five determinations: method, sample fate and what a private buyer pays
DeterminationMethod familySampleTurnaroundRelative cost
PurityReversed-phase HPLC, UVA few mg, non-destructive to batch2–7 days
IdentityLC–MS, optionally MS/MSA few mg3–10 days1–2×
Peptide contentElemental N or quantitative AAASeveral mg2–4 weeks2.5–3×
Bacterial endotoxinKinetic chromogenic LAL or rFC<1 mL reconstituted3–10 days2–3×
SterilityMembrane filtration, 14-day incubationEntire container, destroyed3–4 weeks6–10×
Relative cost is expressed against a single generic-gradient purity run as 1×, from quotations obtained by the Journal from contract laboratories during the year. Sterility pricing assumes a single container rather than a compendial sample of twenty.

What the cake tells you

A lyophilised plug is a physical record of the cycle that produced it. A well-formed cake occupies close to the volume of the solution that was frozen, has a matte, uniform appearance, retains a defined edge where it met the glass, and dissolves rapidly and completely on addition of diluent. That appearance indicates that the product was frozen below its critical formulation temperature and dried without the structure collapsing.

Departures are informative. A shrunken, translucent or glassy plug suggests collapse during primary drying — the ice sublimed faster than the amorphous matrix could hold its structure — which is associated with higher residual moisture and a shorter shelf life. A cake that has partly detached and moves freely suggests mechanical handling after drying, which is cosmetic. A cake showing melt-back at the base, or a visible meniscus line, suggests a shelf temperature excursion. Slow or incomplete reconstitution suggests either collapse or an unfavourable surface.

None of these observations is a purity finding, a sterility finding or an endotoxin finding, and it is important not to overclaim. What they are is the only direct evidence about process control that arrives in the box, and reading them costs nothing. The Journal photographs every cake it receives before opening the vial, for exactly that reason.4

Documentation practice, named and criticised

The Journal tracks the release documentation of twenty companies. On sterility and endotoxin the picture is close to uniform. Every one publishes a purity figure. A minority publish an identity confirmation. Two publish peptide content. On the microbiological attributes, the standard document is silent, and the silence is not annotated: there is no line reading that sterility has not been determined, which would at least be informative.

Some of the practices we would like to see are already in use somewhere in the group. SSA reports peptide content on its certificates, having begun after correspondence with this publication. CPC and SWB describe their fill environment in general terms on request. QST and BCH answered our five questions in full. WXT and FGP declined on the grounds that research-use products are not represented as sterile injectables, which is a legally sound answer that concedes the point of the exercise. Several others did not respond, and we record non-response as non-response rather than as evasion.

What we are criticising is a documentary convention, not the conduct of any company named here. None of the twenty has been shown to us to have misrepresented anything. The convention is that a chemistry certificate stands in for a release package, and it is a convention this trade adopted collectively and could abandon the same way.

111805019-1210 containers20 containers100 containers0.10.512510true contamination rate (% of containers)probability the batch passes (%)
Figure. Probability that the compendial sterility test passes a batch, as a function of true contamination rate, for three sample sizes. The twenty-container sample required for a batch above five hundred units is the middle series.

A note on method and sourcing

The compendial material in this article is drawn from the current general chapters of the United States Pharmacopeia and the European Pharmacopoeia, read in the original rather than in summary, and from the international standards on aseptic processing and on laboratory competence. Where a chapter has changed status recently — as the recombinant reagent chapters have — we say so, because a reader consulting an older edition will find a different framing.

Where the Journal reports a number it obtained itself, it states the laboratory’s accreditation status, the method family, whether method suitability was established, and the number of determinations. Where we report what a company told us, we distinguish an answer from a refusal and a refusal from a non-response, because those three things are routinely collapsed in coverage of this trade and they are not the same.

Corrections to this department are handled by the standards desk, which reads every letter and records the outcome in the log. Readers who believe a paragraph here overstates its evidence are asked to write to standards@compoundjournal.com; readers with documents to send, including certificates they would like read, should write to letters@compoundjournal.com. We do not publish correspondents’ names without permission and we do not identify the source of a certificate.

Readers should hold two facts together, uncomfortable as the combination is. The frameworks described here — endotoxin limits, sterility assurance, particulate ceilings — govern licensed parenteral medicines, and research-use material is under no obligation to meet them. That is a legal fact about obligation. It is not a reassurance, and nobody involved in the trade has ever suggested it was.

References

  1. International Organization for Standardization. ISO 13408-1:2008 — Aseptic processing of health care products, Part 1: General requirements. Geneva, 2008.
  2. United States Pharmacopeia. General Chapter ⟨86⟩ Bacterial Endotoxins Test Using Recombinant Reagents. USP–NF, Rockville, MD.
  3. European Pharmacopoeia. Chapter 2.6.32 — Test for Bacterial Endotoxins Using Recombinant Factor C. Council of Europe, Strasbourg.
  4. “Cake appearance, collapse temperature and residual moisture in lyophilised peptide formulations.” AAPS PharmSciTech. 2019;20(7):286.