The batch number is the only thing connecting the page to the vial

What happens to traceability when bulk material is subdivided, repackaged and relabelled two or three times before sale.

A certificate of analysis makes claims about a batch. The batch number is therefore not an administrative detail but the entire mechanism by which the document attaches to physical material. If the number printed on the certificate does not appear on the vial — not on the box, not on the invoice, not in the listing, on the vial — then the document is a true statement about a quantity of material that may or may not be the quantity in front of you. This is the first thing the Journal checks and the check most often fails, usually for reasons that are administrative rather than sinister.

The header block: identifying the object

The top of a certificate answers the question, what is this document about. A complete header names the product, gives a catalogue or item number, gives the batch or lot number, states the quantity or fill weight, names the manufacturer and the site, and identifies the customer or order where applicable. Some add a chemical name, a sequence in single-letter code, a molecular formula and a molecular weight, all of which are useful because they let a reader check the theoretical values used elsewhere on the page.

The sequence in particular is worth insisting on. A certificate that prints the one-letter sequence has given a reader the means to calculate the expected mass independently, and therefore to check the identity line. Two of the twenty companies in the Journal’s dossier programme do this as standard. It costs nothing and it converts one line of the document from an assertion into a verifiable claim.

What a header should never do is identify the product only by a trade name. A vial described as a proprietary blend with no chemical identity, no formula and no sequence cannot be checked against anything, and a certificate for such a product is a document about a name. This is a documentary observation rather than an accusation, and the remedy is trivial: print the sequence.

What “conforms” conceals

A statement of conformity is a judgement, not a measurement, and the judgement depends on how the reporting party handles results that sit near a limit. If a specification requires not less than 98.0% and a measurement returns 97.9% with a method uncertainty of ±0.4%, does the batch conform? The answer depends entirely on a policy — whether the limit is applied to the measured value, or to the measured value adjusted for uncertainty, and in which direction. Metrological reporting practice has a settled answer here, which is that a result quoted without its uncertainty cannot be compared to a limit at all.1

The accreditation standard for testing laboratories requires that where a statement of conformity is given, the decision rule employed is documented and the report identifies it.2 This is not a technicality. Without a decision rule, “conforms” means whatever the person writing it decided it meant on the day, and two laboratories applying different rules to the same measurement will report different verdicts without either being wrong.

In this market decision rules are essentially unknown, and the practical consequence is that the word carries no information about marginal cases. The Journal therefore reports numbers rather than verdicts wherever a number is available, and where a source supplies only a conformance statement we say so explicitly rather than paraphrasing it as a pass. Readers occasionally find this pedantic. It is the difference between reporting a measurement and repeating an opinion.

A purity limit of ≥95% on material that always reports 99% is not a control. It is a formality with a number attached.

On decorative acceptance criteria

What a batch number is supposed to mean

A batch, or lot, is a defined quantity of material produced in a single process run or a defined series of runs, homogeneous within itself, and identified by a unique code. That definition does real work: it is what makes it meaningful to test a sample and draw conclusions about the whole. If the material identified by one code is not homogeneous — if it was blended from separate syntheses, or filled across several sessions from stock stored differently — then a result on one sample generalises less well than the certificate implies.

In this trade batch codes range from the highly informative to the arbitrary. A code encoding the year, the month, the product and a sequence number tells a reader something and can be checked for internal consistency across documents. A four-digit code with no discernible structure cannot. Neither format is wrong; the difference is whether a reader can detect an anomaly.

The Journal’s dossier programme asks each company how batch codes are constructed and whether one code corresponds to one synthesis, one fill, or one shipment. The answers vary considerably and several companies have not previously been asked. We publish the answers without comment, because a code that identifies a fill session rather than a synthesis is a perfectly reasonable convention as long as a reader knows which convention is in use.

Which elements appear on twenty suppliers’ certificates
ElementCertificates carrying it (of 20)
Product name and batch number20
Purity result20
Date of analysis18
Identity test of any kind14
Appearance13
A name in the signature block11
Date of manufacture10
Specification column present for all tests9
Named method with gradient or wavelength7
Sequence printed in single-letter code6
Retest or expiry date with convention stated5
Water content4
Peptide content3
Counter-ion identity and content2
Two signatures in the regulated pattern2
Statement linking bulk lot to fill lot3
Counts are of the most recent certificate supplied to the Journal by each of the twenty companies in the dossier programme, at the last quarterly cycle. Several companies supply additional information on request that does not appear on the standard document; those cases are credited here only where the element appears on the certificate itself.

Check the vial, not the box

The single most common documentary failure the Journal encounters is a batch number on the certificate that does not appear on the vial. The variants are instructive. Sometimes the number is on the outer carton and not the vial, which means the connection between document and material depends on the carton having been packed correctly. Sometimes the vial carries a different number entirely, and the certificate corresponds to an earlier lot. Sometimes the vial carries no number at all, in which case the certificate cannot be attached to it by any means.

These situations are not equivalent and none of them is, on its own, evidence of misconduct. Subdivision and repackaging generate new identifiers legitimately, and a reseller filling vials from bulk may reasonably supply the synthesis house’s certificate for the bulk material while assigning its own fill lot. What is not reasonable is leaving the reader to guess which object the document describes, because that guess is exactly what a certificate exists to remove.

The remedy is a single line: a statement of the relationship between the certificate’s lot and the vial’s lot. “Filled from bulk lot X as fill lot Y on date Z” is eleven words and resolves the entire question. Three of the twenty companies in our programme now print something to this effect, two of them after we asked.

Three dates, and the conventions behind them

Date of manufacture is when the material was made. Date of analysis is when the reported tests were performed. Retest date is the date by which the material should be re-examined if it is to continue to be used, and expiry date is the date after which it should not be used at all. The last two rest on different evidence: an expiry date implies stability data supporting the claim over that period, while a retest date implies a policy of re-examination in the absence of such data.

In this market the two are used interchangeably, and the substitution matters. A vial marked with a two-year expiry, where no stability study exists, is carrying a claim its documentation cannot support. The same vial marked with a two-year retest date is carrying a much weaker and entirely defensible statement: we have not established shelf life, so look again by this date. The second is honest and the first is not, and the difference is one word.

What follows for a reader is a specific question to ask: on what basis. A supplier that can point to real-time or accelerated stability data for the sequence in question has something. A supplier that assigned twenty-four months because that is what the form said has something else, and the international framework for setting such limits is explicit about the evidence required.3

109856137132024 audit2026 audit7143060120180365days between manufacture and analysiscumulative % of certificates
Figure. Cumulative share of audited certificates whose date of analysis falls within a given number of days of manufacture, comparing the Journal’s 2024 audit with the 2026 cycle. Documents missing either date are excluded from both series.

The certificate is a snapshot, and the vial has aged

Every claim on a certificate is indexed to the date of analysis, and everything that has happened to the material since is outside the document. For lyophilised peptides stored cold, dry and dark, the rate of change is slow but not zero: deamidation proceeds even in the solid state at a rate that depends on residual water, oxidation proceeds in the presence of air and light, and aggregation can occur after a temperature excursion that leaves no other trace.4

The practical significance depends on the interval. A certificate dated three weeks before shipment describes material that is, for most purposes, the material in the vial. A certificate dated fourteen months before shipment describes an earlier object. The Journal’s audit of certificates supplied through the dossier programme found a median interval between manufacture and analysis of eleven days, which is reassuring, and a median interval between analysis and the customer receiving the vial of somewhat over four months, which is the number nobody reports.

None of this argues for retesting every vial. It argues for reading the date, which takes two seconds, and for treating purity figures as historical rather than current. It also argues for taking the appearance line seriously, since a change in the cake is one of the few observations a buyer can make that bears on what has happened since the document was written.

The ten-minute check

Minute one: find the batch number on the certificate and find it on the vial. Not the carton. If they do not match, or the vial has no number, stop and ask the supplier what the relationship is. Minutes two and three: find the date of manufacture and the date of analysis, and compute the interval. Then compute the interval between the date of analysis and today.

Minutes four and five: read the test table and count the columns. If the specification column is missing, the results cannot be assessed. If the method column is missing or says only HPLC, the purity figure cannot be compared with anybody else’s. Minute six: check the identity line for a theoretical mass, and check whether the convention — monoisotopic or average — is stated. Minute seven: read the signature block for a name and a role.

Minutes eight to ten: list what is not there. Content, water, counter-ion, residual solvent, endotoxin, sterility. Then decide whether any of those matter for what you are doing, which is a question only the reader can answer. The exercise does not establish that a certificate is right or wrong. It establishes whether the document can be checked at all, and in the Journal’s experience roughly a third of certificates in general circulation fail before minute five. Readers who work through this and find something they cannot interpret are welcome to write to standards@compoundjournal.com.

A manufacturer’s certificate reaches the whole batch. An independent report reaches an independent measurement. Buyers credit each with both.

Noor Haddadin, Supply Chain Editor

How this publication handles certificates

Four rules, arrived at over two years and revised twice. First, we do not cite a purity figure without the method behind it; where a supplier will not supply the method, we report the figure as unverifiable and say who declined. Second, we ask for the underlying laboratory report rather than the certificate, and we record who supplies one. Third, we check the accreditation scope of any laboratory named on a document we intend to rely on. Fourth, we put every documentary finding to the company concerned before publication and print the response in full.

The fourth rule is the one that has changed our coverage most. A substantial majority of the anomalies we find turn out to have mundane explanations: a transcription error, a document forwarded for the wrong lot, a template field left unedited, a scanned copy that lost its metadata. Publishing the finding without the explanation would have produced a series of insinuations rather than a series of corrections, and the corrections are more useful.

The rules also mean we publish less than we could. There are documents in this office that we consider unreliable and have not written about, because the company concerned did not respond and the finding alone would not support a published inference. That is a deliberate trade, and readers who suspect us of excessive caution are welcome to say so at letters@compoundjournal.com, where several already have.

Documentary discrepancies in 63 certificates audited by the Journal
FindingCertificatesResolved on enquiryUnresolved
Batch number absent from the vial itself19145
No specification column for one or more tests17116
Method stated only as an acronym1697
Date of manufacture absent13103
No name in the signature block1174
Expiry date with no supporting stability data963
Molecular weight inconsistent with printed sequence330
Chromatogram identical to one on another document211
Sixty-three certificates supplied to the Journal between the first quarter of 2025 and the second quarter of 2026, covering the twenty companies in the dossier programme and eleven others. “Resolved on enquiry” means the company supplied an explanation or corrected document that the standards desk accepted. No finding in this table is presented as evidence of misconduct by any company.

A necessary distinction between a bad document and a bad product

Almost nothing in this article supports an inference about the contents of a vial. A certificate missing a specification column, an unsigned footer, a stale date of analysis and a batch number that appears only on the carton is a poor document. The material it accompanies may be excellent, and in the Journal’s experience frequently is: the analytical work behind these products is often better than the paperwork that reports it, because the paperwork is produced by a commercial function and the analysis by a laboratory.

The reverse also holds. A beautifully constructed certificate with four columns, two signatures and a named method is evidence of a functioning documentary process and is not evidence about the vial either, since a document cannot testify to material it does not accompany. This is why the Journal reports documents as documents and material as material, and declines to convert one into a claim about the other.

We labour the point because the alternative is a genre of coverage that treats documentary weakness as proof of dishonesty, and that genre is both unfair and useless. Unfair because most documentary weakness in this trade is inherited convention rather than intent. Useless because it gives a reader nothing to do. Reading the document properly gives a reader something to do, which is the entire purpose of this piece.

What remains genuinely absent from this market is any documentation of what happens to a vial between the date of analysis and the day it is opened. Every certificate is a snapshot at manufacture; nothing records the four months in transit and storage that follow. Until somebody prices a cheap release-and-receipt check, the honest statement about any research vial is that its purity was measured once, some time ago, by a method that may not be stated.

References

  1. “Measurement uncertainty, significant figures and the reporting of chromatographic purity.” Analytical Chemistry. 2018;90(3):1476–1484.
  2. International Organization for Standardization. ISO/IEC 17025:2017, clause 7.8.6, “Reporting statements of conformity,” on the requirement to document and identify the decision rule applied.
  3. International Council for Harmonisation. Q6B: Specifications — Test Procedures and Acceptance Criteria for Biotechnological/Biological Products. 1999.
  4. “Solid-state stability of lyophilised synthetic peptides: residual water, deamidation and oxidation on storage.” Journal of Peptide Science. 2021;27(4):e3298.