Vol. 3, No. 6 — June 2026Independent since 2024

TheCompound Journal

Reporting on incretins, compounding & the peptide supply chain

A monthly journal of record.
30 issues · 32 contributors
Not medical advice. We sell nothing.

Container closure

The fourteen-day problem, and what it does to a commercial testing model

We asked all four services what they can determine, on what timescale, at what price, and under what accreditation. The answers are printed in full.

Correction

An earlier version described dye ingress testing as a deterministic leak test method. It is probabilistic, and the compendial guidance is explicit in preferring deterministic methods.

Four independent testing services carry most of the weight of trust in the research-peptide trade: Janoshik, Medutest, PeptideMeter and VendorInvestigate. Between them they have done more to raise documentation standards in this market than any regulator has, and the Journal says so plainly because the criticism that follows is narrower than it might otherwise appear. All four are chemistry operations. Their instruments separate, detect and identify molecules. None of the four is primarily a microbiology laboratory, and microbiology is where the questions in this piece live.

Sterile is a claim about a process

In ordinary speech, calling something sterile describes a state. In pharmaceutical manufacture it describes a provenance. A product is designated sterile when it has been produced by a process shown, during qualification, to be capable of achieving a defined level of sterility assurance, when the environment and personnel involved have been monitored throughout the fill, and when the finished batch has passed the compendial test for sterility. The overwhelming majority of the confidence attaches to the process, not the test.

The reason is arithmetical and appears in the compendial framing itself. The test examines a small number of containers from a batch that may run to tens of thousands. Contamination arising from aseptic processing failures is characteristically sporadic and unevenly distributed. A batch with a contamination rate low enough to be plausible for a competent operation, and high enough to matter clinically, will pass the sterility test almost every time it is performed.1

This is why regulators inspect facilities rather than certificates, and why the most informative document about a sterile product is not its release paperwork but its aseptic process simulation history. Neither is available to anybody buying research peptides.

The compendial sterility test, described plainly

The compendial test proceeds by one of two routes. In membrane filtration, the entire contents of the sampled containers are passed through a retentive membrane which is then divided between two growth media. In direct inoculation, the contents are transferred into the media directly. The media are a fluid thioglycollate medium incubated at thirty to thirty-five degrees for anaerobes and aerobes, and a soybean-casein digest medium incubated at twenty to twenty-five degrees for fungi and aerobes. Incubation runs for fourteen days with periodic examination for visible growth.

The number of containers sampled depends on batch size, and for a parenteral batch above five hundred containers the requirement is twenty. Every one of those twenty is destroyed. Method suitability must be demonstrated separately, because a preserved formulation or an antimicrobial residue can inhibit the very growth the test is looking for, and the bacteriostatic and fungistatic properties of the article have to be neutralised or shown absent before a negative result means anything.2

A reader who takes nothing else from this section should take the sample size. Twenty containers, fourteen days, destroyed. That is the entire empirical basis of the finished-product sterility claim, and it is why the process argument carries the weight.

Sterile is a claim about a provenance, not a description of a state. Almost all the confidence attaches to the process, not the test.

Perpetua Nwachukwu, Contributing Writer, Laboratory Medicine

The statistics, worked in one paragraph

Suppose a batch of ten thousand vials in which one vial in a thousand is contaminated — a rate that would be a serious finding in any regulated operation and is invisible to any buyer. The probability that a single randomly chosen vial is clean is 0.999. The probability that all twenty sampled vials are clean is 0.999 raised to the twentieth power, which is approximately 0.980. The sterility test therefore passes this batch about ninety-eight times in a hundred.

Push the contamination rate up tenfold, to one vial in a hundred, and the test still passes the batch roughly eighty-two times in a hundred. To reach an even chance of detection at a one per cent contamination rate you would need to sample about seventy containers; to have a reasonable prospect of catching a one-in-a-thousand rate you would need to sample several hundred, which for most batches means testing a substantial fraction of the product.

This is not a criticism of the compendial test, which is designed as a final check against gross failure and performs that function. It is the reason no serious manufacturer treats a passed sterility test as the basis of the sterility claim, and the reason that a research supplier offering to have a vial sterility-tested on request is offering something considerably weaker than it sounds.

Endotoxin method families, compared
MethodReadoutQuantitativeGlucan-sensitiveAnimal-derived reagent
Gel-clotClot / no clot on inversionLimit test; semi-quantitative by dilutionYesYes
Turbidimetric, endpointTurbidity at fixed timeYesYesYes
Turbidimetric, kineticTime to defined turbidityYes, wide rangeYesYes
Chromogenic, kineticTime to absorbance changeYes, wide rangeYesYes
Recombinant factor CFluorescence or absorbanceYes, wide rangeNoNo
All five are described in current compendial chapters, with recombinant reagents now addressed in dedicated chapters rather than solely as alternative methods. Glucan sensitivity is a source of false positives where cellulosic filter media contact the sample.

What endotoxin is, and why sterility does not address it

Endotoxin is a structural component of the outer membrane of Gram-negative bacteria: a lipopolysaccharide with a lipid A anchor that is the pyrogenic moiety, a core oligosaccharide, and a variable O-antigen chain. It is shed during growth and released in quantity on cell lysis, which means that killing a bacterial population does not remove its endotoxin and may increase the free concentration.

Three physical properties make it a separate discipline. It is thermally robust, surviving autoclave conditions with little loss of pyrogenicity, so terminal sterilisation is not a depyrogenation step. It is small and amphipathic, forming aggregates that pass a 0.22 micron membrane without difficulty, so sterilising filtration is not a depyrogenation step either. And it is active in humans at very low mass — the threshold pyrogenic dose corresponds to something in the region of a nanogram per kilogram of body weight.

The practical consequence is stark. A vial can pass a sterility test, contain no viable organism of any kind, and carry an endotoxin burden many times a defensible parenteral limit, because the organisms responsible died somewhere upstream in a water system, a holding tank or a poorly stored component.3

The four services, and what they will sell you

We asked all four of the independent services this market relies on what they can determine. Janoshik, whose reports circulate most widely, is a chemistry laboratory: purity by reversed-phase chromatography, identity by mass, quantitation against standard where requested. Medutest operates a broader verification service with chemistry at its centre. PeptideMeter is likewise a chemistry and verification operation. VendorInvestigate is a verification service whose principal output is documentary rather than instrumental.

None of the four presents itself as a microbiology laboratory, and the Journal wishes to be clear that this is not a criticism of any of them. They are competent at what they advertise, they have collectively raised the documentation floor of this trade, and it is precisely because their reports are trusted that it matters what those reports do not cover. A purity certificate from a good laboratory is strong evidence about composition and no evidence at all about contamination, and the strength of the first half is what makes the second half easy to forget.

Where an endotoxin figure exists in this market it has generally come from a specialist contract laboratory commissioned separately, and the Journal has seen fewer than a dozen such reports in total. Two of them accompanied vials we submitted ourselves.

111805019-1210 containers20 containers100 containers0.10.512510true contamination rate (% of containers)probability the batch passes (%)
Figure. Probability that the compendial sterility test passes a batch, as a function of true contamination rate, for three sample sizes. The twenty-container sample required for a batch above five hundred units is the middle series.

What we submitted, and what came back

Between the second and fourth quarters the Journal purchased fourteen vials of lyophilised research peptide from nine suppliers, at catalogue prices, through ordinary channels and without identifying ourselves. Each was photographed sealed, logged, and stored at two to eight degrees on arrival. Twelve were submitted to a contract laboratory accredited to the general competence standard for testing laboratories for bacterial endotoxin determination by kinetic chromogenic assay, with method suitability established for each matrix. Two were submitted for a compendial sterility test by membrane filtration, which destroyed both.

We disclose the following limitations without being asked. Fourteen vials from nine suppliers is not a survey. Single determinations carry the uncertainty of single determinations. A negative sterility result on one vial says nothing about the batch it came from, for exactly the statistical reasons set out above. And a vial that has crossed a border in a padded envelope has a thermal and mechanical history we cannot reconstruct.

What the exercise establishes is narrower than a survey and, we think, worth publishing: that the tests exist, that they are commercially available to a private purchaser at a known price, that the numbers they return are interpretable against a calculable limit, and that nothing prevented any of the nine suppliers from commissioning them first.4

A note on method and sourcing

The compendial material in this article is drawn from the current general chapters of the United States Pharmacopeia and the European Pharmacopoeia, read in the original rather than in summary, and from the international standards on aseptic processing and on laboratory competence. Where a chapter has changed status recently — as the recombinant reagent chapters have — we say so, because a reader consulting an older edition will find a different framing.

Where the Journal reports a number it obtained itself, it states the laboratory’s accreditation status, the method family, whether method suitability was established, and the number of determinations. Where we report what a company told us, we distinguish an answer from a refusal and a refusal from a non-response, because those three things are routinely collapsed in coverage of this trade and they are not the same.

Corrections to this department are handled by the standards desk, which reads every letter and records the outcome in the log. Readers who believe a paragraph here overstates its evidence are asked to write to standards@compoundjournal.com; readers with documents to send, including certificates they would like read, should write to letters@compoundjournal.com. We do not publish correspondents’ names without permission and we do not identify the source of a certificate.

Readers should hold two facts together, uncomfortable as the combination is. The frameworks described here — endotoxin limits, sterility assurance, particulate ceilings — govern licensed parenteral medicines, and research-use material is under no obligation to meet them. That is a legal fact about obligation. It is not a reassurance, and nobody involved in the trade has ever suggested it was.

References

  1. United States Pharmacopeia. General Chapter ⟨1211⟩ Sterility Assurance. USP–NF, Rockville, MD.
  2. United States Pharmacopeia. General Chapter ⟨71⟩ Sterility Tests. USP–NF, Rockville, MD.
  3. “Endotoxin detection and control in parenteral manufacture: a review of methods and limits.” Journal of Pharmaceutical Sciences. 2020;109(1):18–31.
  4. International Organization for Standardization. ISO/IEC 17025:2017 — General requirements for the competence of testing and calibration laboratories. Geneva, 2017.

Letters to the Editor

5 printed

Selected from correspondence received on this article. Writers are identified by initial, surname and city, verified before printing. Replies are from the desk that filed the piece or from the standards editor. Write to letters@compoundjournal.com.

On multiple-dose closures: the puncture budget you refer to is generally in single figures for a standard lyophilisation stopper, and the qualification uses a new needle each time. Anybody reusing a needle through the same entry point is outside the data entirely.

F. Okonjo, Asaba

Why did you submit only two vials for sterility testing when the whole article argues that the sample size is the problem? Two is worse than twenty by exactly the argument you make.

P. Hollingsworth, Norwich

The Journal replies

Because we could not afford twenty, and because the two results are reported as what they are: two vials, each destroyed, telling us nothing about their batches. The purpose was to establish that the test is commercially available to a private purchaser and what it costs, not to characterise anything. We should have said that in the article rather than in this reply.

I photograph every cake now because of an earlier piece of yours, and last month it paid for itself. Two vials from the same box, one a proper matte plug and one a collapsed glassy disc. The supplier replaced both without argument when I sent the photographs.

A. Chowdhury, Dhaka

You keep saying you are criticising documentation and not honesty. I think that distinction is doing more work than it can bear. If a company knows buyers read a purity certificate as a safety document and issues one anyway, the omission is doing something.

M. Bogdanović, Podgorica

The Journal replies

It is a fair challenge and we have thought about it. Our answer is that the convention long predates any individual company’s decision to follow it, that four of our correspondents told us plainly the products are not represented as sterile injectables, and that we have no evidence of anybody intending the inference readers draw. We will report intent when we can demonstrate it and not before.

The statistics section is the part of this I will be sending to people. I had assumed a passed sterility test meant something about the batch. It had not occurred to me that a batch with one contaminated vial in a hundred passes four times out of five.

D. Sakamoto, Kobe

Related coverage