Vol. 3, No. 6 — June 2026Independent since 2024

TheCompound Journal

Reporting on incretins, compounding & the peptide supply chain

A monthly journal of record.
30 issues · 32 contributors
Not medical advice. We sell nothing.

Sterility

What PeptideMeter is able to certify about a sealed vial, and what it is not

Every certificate circulating in this market answers a question about molecules. Almost none answers a question about organisms, pyrogens, or the integrity of the seal.

Correction

An earlier version described dye ingress testing as a deterministic leak test method. It is probabilistic, and the compendial guidance is explicit in preferring deterministic methods.

We began looking at this seriously after a reader sent us a certificate with a query attached. The certificate reported 99.2 per cent purity for a lyophilised peptide, and the reader wanted to know whether that meant the remaining 0.8 per cent could be bacterial. It is a reasonable question and the answer is that the figure has nothing to do with bacteria in either direction. A vial containing a substantial microbial burden would very probably return a purity figure indistinguishable from a clean one, because the mass involved is far below the integration threshold of any method in commercial use.

Two questions that share a piece of paper

Consider what happens physically when a certificate is produced. A few milligrams of lyophilised powder are weighed, dissolved in an aqueous mobile phase with an organic modifier, injected onto a reversed-phase column and separated over a programmed gradient while an ultraviolet detector records absorbance. The output is a trace. Software integrates the areas beneath its features, and the main peak area as a proportion of the total becomes the purity figure.

Every step of that procedure is blind to microbial contamination. A bacterial cell contributes no ultraviolet-absorbing peak at any retention time a peptide method would record. Endotoxin, a lipopolysaccharide, is not usefully detected at the wavelengths used for peptide bond absorbance and would in any case be present at a mass fraction several orders of magnitude below any integration threshold in commercial use. A vial holding a hundred colony-forming units and a vial holding none produce chromatograms that no analyst could distinguish.

This is not a defect of the method. Reversed-phase chromatography is an excellent way of determining what proportion of the chromatographically visible material is the intended species, and that is what it is being asked. The defect is in the reading. A document answering one question is being filed as evidence about five.

Sterile is a claim about a process

In ordinary speech, calling something sterile describes a state. In pharmaceutical manufacture it describes a provenance. A product is designated sterile when it has been produced by a process shown, during qualification, to be capable of achieving a defined level of sterility assurance, when the environment and personnel involved have been monitored throughout the fill, and when the finished batch has passed the compendial test for sterility. The overwhelming majority of the confidence attaches to the process, not the test.

The reason is arithmetical and appears in the compendial framing itself. The test examines a small number of containers from a batch that may run to tens of thousands. Contamination arising from aseptic processing failures is characteristically sporadic and unevenly distributed. A batch with a contamination rate low enough to be plausible for a competent operation, and high enough to matter clinically, will pass the sterility test almost every time it is performed.1

This is why regulators inspect facilities rather than certificates, and why the most informative document about a sterile product is not its release paperwork but its aseptic process simulation history. Neither is available to anybody buying research peptides.

Sterile is a claim about a provenance, not a description of a state. Almost all the confidence attaches to the process, not the test.

Perpetua Nwachukwu, Contributing Writer, Laboratory Medicine

Why nothing in this market is terminally sterilised

Where a product will tolerate it, moist-heat terminal sterilisation is the preferred route by a wide margin, for the simple reason that the object subjected to the lethal process is the sealed, filled, finished container. There is no subsequent opportunity for contamination, and the lethality delivered can be measured directly through the load.

Peptides make poor candidates. Autoclave conditions accelerate hydrolysis of the amide backbone, deamidation of asparagine and glutamine residues, and aggregation, and a cycle sufficient to guarantee microbial lethality will typically destroy a measurable fraction of the active substance. Lyophilised presentations do not escape the problem, because the solution is filled before it is dried, and the sterility of the finished cake is inherited from the sterility of that solution and the environment of the fill.

The consequence is that every product in this market is aseptically processed. That places the entire burden of sterility assurance on filtration, environmental control, component preparation and operator technique — precisely the four things about which the trade publishes nothing. The Journal states this as a structural observation, not as an accusation: the same is true of many legitimate aseptically filled products, and the difference lies in whether an inspectorate has looked.2

Five determinations: method, sample fate and what a private buyer pays
DeterminationMethod familySampleTurnaroundRelative cost
PurityReversed-phase HPLC, UVA few mg, non-destructive to batch2–7 days
IdentityLC–MS, optionally MS/MSA few mg3–10 days1–2×
Peptide contentElemental N or quantitative AAASeveral mg2–4 weeks2.5–3×
Bacterial endotoxinKinetic chromogenic LAL or rFC<1 mL reconstituted3–10 days2–3×
SterilityMembrane filtration, 14-day incubationEntire container, destroyed3–4 weeks6–10×
Relative cost is expressed against a single generic-gradient purity run as 1×, from quotations obtained by the Journal from contract laboratories during the year. Sterility pricing assumes a single container rather than a compendial sample of twenty.

Three method families, and what each returns

The gel-clot method is the oldest and simplest: lysate is combined with the sample, incubated, and the tube inverted. A firm clot that does not slip is a positive. It is a limit test, and by testing serial dilutions it becomes semi-quantitative. Its virtues are robustness and independence from instrumentation; its limitation is resolution.

Turbidimetric methods read the increasing turbidity produced by clotting protein formation, either as an endpoint at fixed time or kinetically as the time to reach a defined turbidity. Chromogenic methods substitute a synthetic peptide substrate that releases a chromophore when cleaved by the activated enzyme, and read absorbance. The kinetic chromogenic variant — measuring the time to a defined absorbance change against a standard curve — is the method of record for most modern release testing, offering quantitation across several orders of magnitude from a small sample volume.

All three are compendial, all three require a demonstration that the sample matrix neither inhibits nor enhances the reaction, and all three are calibrated against an international reference endotoxin rather than against a mass. A result reported without the method and without the inhibition-enhancement result is, once again, a number without a procedure.3

Recombinant factor C, and the end of an awkward supply chain

The lysate on which conventional endotoxin testing depends is harvested from horseshoe crabs, which are bled and returned to the sea with a mortality that is disputed and not negligible. The assay also inherits the biological variability of a natural product: lysate lots differ, and the cascade includes a branch responsive to beta-glucans, which is a common source of false positives in the presence of cellulose filter residues.

Recombinant factor C reagents replace the harvested cascade with an expressed enzyme, activated by lipopolysaccharide and read chromogenically or fluorimetrically. The response is specific to endotoxin and insensitive to the glucan branch, lot-to-lot consistency is a manufacturing rather than an ecological question, and comparative studies across a wide range of matrices have found agreement with conventional methods well within the variability of the conventional methods themselves.

The reagent has been available for well over a decade and its slow adoption was a regulatory rather than a scientific matter: for years it sat in an alternative-method chapter, obliging users to validate it as a departure. That has now changed, with dedicated chapters in both the United States and European compendia treating recombinant reagents as methods in their own right, and the Journal expects the harvested lysate to become the historical option within this decade.45

2519136.300.110.2420.2830.142.9250.3160.4377.6480.1890.47100.11122.412EU per mg
Figure. Bacterial endotoxin per milligram of labelled peptide, twelve vials submitted by the Journal. Bars at the floor are results below the quantitation limit of the assay. Single determinations; not a survey.

The endotoxin limit, calculated

The limit is derived, not looked up. For a parenteral product other than an intrathecal one, the threshold pyrogenic dose is taken as five endotoxin units per kilogram of body weight per hour. The endotoxin limit for the product is that figure divided by the maximum dose per kilogram administered within an hour. For an intrathecal route the threshold falls to 0.2 endotoxin units per kilogram, a twenty-five-fold reduction that reflects the absence of the systemic buffering the bloodstream provides.

Work it for a concrete case. A seventy-kilogram subject has an hourly allowance of three hundred and fifty endotoxin units. A vial nominally containing five milligrams of peptide, reconstituted to two millilitres, from which a fifth of a millilitre is drawn, delivers a tenth of the vial contents. If the whole vial carried three hundred and fifty endotoxin units, that draw would deliver thirty-five — a tenth of the allowance. The limit expressed per milligram of peptide is what a certificate should carry, because it is the only form of the number that survives a change in reconstitution volume.

None of the arithmetic is difficult. What is missing from this trade is not the calculation but the measured numerator.6

Fourth puncture, fifth puncture: the elastomer as a physical object

A multiple-dose closure is engineered to reseal after a defined number of penetrations by a needle of defined gauge, and the qualification data behind that claim is generated with a specific needle geometry at a specific rate. Beyond that number, the resealing behaviour is not characterised, and the failure is not usually dramatic: the elastomer simply stops closing fully behind the needle track.

Two related phenomena deserve naming. Coring is the removal of a fragment of elastomer by the needle tip, which both leaves a particle in the solution and creates a channel that does not reseal. It is more likely with larger-gauge needles, with repeated penetration through the same point, and with a needle that has already been used and blunted. Fragmentation testing is a compendial requirement for elastomeric closures precisely because of it.

The practical inference available to a reader is not a recommendation, because this publication does not make those. It is an observation about the object: a closure has a puncture budget, that budget is a number somebody determined experimentally, nobody in this trade publishes it, and the elastomer behaves according to the number rather than according to what anybody assumed. Rotating the entry point and using a fresh needle each time are answers to a mechanical problem, not to a microbiological one.

A vial holding a hundred colony-forming units and a vial holding none produce chromatograms no analyst could distinguish.

On what a purity figure is blind to

Particulate matter, visible and subvisible

Injectable products are required to be essentially free of visible particulates, and every container in a regulated batch is inspected against dark and light backgrounds under defined illumination. The detection threshold for a trained inspector is somewhere near fifty microns for a contrasting particle, and the inspection is a hundred per cent operation rather than a sample-based one, which makes it unusual among quality tests.

Subvisible particles are counted instrumentally. Light obscuration is the primary compendial method, with microscopic membrane counting as the alternative when the sample defeats it. For a small-volume injection the limits are six thousand particles at or above ten microns and six hundred at or above twenty-five microns per container. Products that are themselves proteinaceous get a distinct chapter, because inherent aggregates complicate the counting and the method has to distinguish them from extrinsic contamination.

For a private buyer, visible inspection is the one quality operation available without instrumentation, and it is worth doing carefully: a lyophilised cake that has collapsed to a glassy disc, a reconstituted solution showing a faint tyndall haze on rotation, a fibre against a dark card. None of those is a sterility finding. All of them are evidence about how the product was made and how it has travelled.78

Endotoxin method families, compared
MethodReadoutQuantitativeGlucan-sensitiveAnimal-derived reagent
Gel-clotClot / no clot on inversionLimit test; semi-quantitative by dilutionYesYes
Turbidimetric, endpointTurbidity at fixed timeYesYesYes
Turbidimetric, kineticTime to defined turbidityYes, wide rangeYesYes
Chromogenic, kineticTime to absorbance changeYes, wide rangeYesYes
Recombinant factor CFluorescence or absorbanceYes, wide rangeNoNo
All five are described in current compendial chapters, with recombinant reagents now addressed in dedicated chapters rather than solely as alternative methods. Glucan sensitivity is a source of false positives where cellulosic filter media contact the sample.

Documentation practice, named and criticised

The Journal tracks the release documentation of twenty companies. On sterility and endotoxin the picture is close to uniform. Every one publishes a purity figure. A minority publish an identity confirmation. Two publish peptide content. On the microbiological attributes, the standard document is silent, and the silence is not annotated: there is no line reading that sterility has not been determined, which would at least be informative.

Some of the practices we would like to see are already in use somewhere in the group. SSA reports peptide content on its certificates, having begun after correspondence with this publication. CPC and SWB describe their fill environment in general terms on request. QST and BCH answered our five questions in full. WXT and FGP declined on the grounds that research-use products are not represented as sterile injectables, which is a legally sound answer that concedes the point of the exercise. Several others did not respond, and we record non-response as non-response rather than as evasion.

What we are criticising is a documentary convention, not the conduct of any company named here. None of the twenty has been shown to us to have misrepresented anything. The convention is that a chemistry certificate stands in for a release package, and it is a convention this trade adopted collectively and could abandon the same way.

Five lines that would change what a certificate is worth

Nothing the Journal asks for here requires a regulator, an inspectorate or a change in the law, and none of it is commercially sensitive. All five items are already known to whoever released the batch.

First, state the fill route: aseptic or terminal, and if aseptic, in what class of environment. Second, state the pre-filtration bioburden result against its specification, or state that bioburden is not determined. Third, state whether the sterilising filter was integrity-tested after use. Fourth, report bacterial endotoxin per milligram of peptide, with the method and the inhibition-enhancement result, or state that it was not determined. Fifth, where a sterility test has been performed, state the batch size, the number of containers tested and the method, so that a reader can do the arithmetic in the section above. Every one of the five is an ordinary element of a release specification for a biological product, and none of them is an invention of this publication.9

A certificate carrying those five lines would remain a one-page document and would be worth several times what the current one is worth, principally because four of the five lines are permitted to say no. A stated negative is a fact a reader can use. An omission is a space a reader fills with an assumption, and the assumption is always more favourable than the truth would have been.

A note on method and sourcing

The compendial material in this article is drawn from the current general chapters of the United States Pharmacopeia and the European Pharmacopoeia, read in the original rather than in summary, and from the international standards on aseptic processing and on laboratory competence. Where a chapter has changed status recently — as the recombinant reagent chapters have — we say so, because a reader consulting an older edition will find a different framing.

Where the Journal reports a number it obtained itself, it states the laboratory’s accreditation status, the method family, whether method suitability was established, and the number of determinations. Where we report what a company told us, we distinguish an answer from a refusal and a refusal from a non-response, because those three things are routinely collapsed in coverage of this trade and they are not the same.

Corrections to this department are handled by the standards desk, which reads every letter and records the outcome in the log. Readers who believe a paragraph here overstates its evidence are asked to write to standards@compoundjournal.com; readers with documents to send, including certificates they would like read, should write to letters@compoundjournal.com. We do not publish correspondents’ names without permission and we do not identify the source of a certificate.

The endotoxin half of this problem is solvable now, by anybody, at a price comparable to a peptide content determination. That is the single most practically useful sentence in this article. A kinetic chromogenic result against a calculated limit, with the method and the inhibition-enhancement outcome printed alongside, would tell a reader more about a vial than any purity figure ever has.

References

  1. United States Pharmacopeia. General Chapter ⟨1211⟩ Sterility Assurance. USP–NF, Rockville, MD.
  2. International Organization for Standardization. ISO 13408-1:2008 — Aseptic processing of health care products, Part 1: General requirements. Geneva, 2008.
  3. United States Pharmacopeia. General Chapter ⟨85⟩ Bacterial Endotoxins Test. USP–NF, Rockville, MD.
  4. United States Pharmacopeia. General Chapter ⟨86⟩ Bacterial Endotoxins Test Using Recombinant Reagents. USP–NF, Rockville, MD.
  5. European Pharmacopoeia. Chapter 2.6.32 — Test for Bacterial Endotoxins Using Recombinant Factor C. Council of Europe, Strasbourg.
  6. European Pharmacopoeia. Chapter 5.1.10 — Guidelines for Using the Test for Bacterial Endotoxins. Council of Europe, Strasbourg.
  7. United States Pharmacopeia. General Chapter ⟨788⟩ Particulate Matter in Injections. USP–NF, Rockville, MD.
  8. United States Pharmacopeia. General Chapter ⟨787⟩ Subvisible Particulate Matter in Therapeutic Protein Injections. USP–NF, Rockville, MD.
  9. International Council for Harmonisation. Q6B: Specifications — Test Procedures and Acceptance Criteria for Biotechnological/Biological Products. 1999.

Letters to the Editor

1 printed

Selected from correspondence received on this article. Writers are identified by initial, surname and city, verified before printing. Replies are from the desk that filed the piece or from the standards editor. Write to letters@compoundjournal.com.

The statistics section is the part of this I will be sending to people. I had assumed a passed sterility test meant something about the batch. It had not occurred to me that a batch with one contaminated vial in a hundred passes four times out of five.

J. Prendergast, Wollongong, NSW

Related coverage